12. Remove seven screws-A and drum
grounding plate and two grounding ter-
minals.
13. Remove the AC inlet.
14. Remove two screws and two grounding
terminals.
15. Remove one connector.
16. Remove the PWB connector between
connect-L PWB and power source unit.
17. Remove the power source unit.
AC inlet
Drum
grounding
plate
Screw
(M3)
Grounding
terminal
Connect-L PWB
Connector
Screws
1-5-40
Screw
(M3)
Screw
Screw
Grounding
terminal
Screw
Screw
(M3)
Figure 1-5-60
PWB connector
Grounding
terminals
Power source unit
Figure 1-5-61