8
Appliance Setup
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
fi rebox.
B. Top to Rear Vent Conversion
KIT CONTENTS: Rear vent grille; NG orifi ce (.113); LP
orifi ce (.063)
TOOLS REQUIRED: Power drill; #2 Phillips bit; high-temp
silicone sealant (optional.)
Remove top trivet, if installed. Remove vent pipe
Figure 8.1
adapter and gasket. If gasket breaks, apply high-temperature
silicone to the bottom of the adapter before installing as indi-
cated in Figure 8.6.
CAUTION
Sharp Edges
• Wear protective gloves
and safety glasses during
installation.
Remove inner collar adapter
Figure 8.2
Figure 8.3
access plate and gasket. Save the screws.
Figure 8.4
attach with the four screws previously removed.
Figure 8.5
Quadra-Fire • Topaz • 7009-113 Rev. Q • 6/14
Remove rear valve cover shield. Remove rear
Place cover plate and gasket over top vent and
Insert inner collar adapter to rear vent flue.