Appliance Setup
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
firebox.
B. Leg Leveling System
Thread Allen bolts through nuts until flush. The
Figure 8.1
Allen bolts and nuts are included in the component pack inside
the appliance firebox.
Slide assembled nuts and bolts into the slots on
Figure 8.2
the legs with the nuts on the bottom.
Use a 5/32 in. 4mm) Allen wrench to adjust legs
Figure 8.3
up and down to desired level.
September 1, 2008
C. Flue Restrictor Installation
When your installation falls within a shaded area on the
vent graph (page 11) a flue restrictor must be installed
for proper operation.
Figure 8.4
removal of the baffle located inside the firebox. Remove the
baffle by first removing the two screws holding the baffle in
place (one on each side). Lift the baffle out of the bracket
along the back of the firebox, angle the baffle slightly and
remove it from the firebox.
Figure 8.5
located in the back of the firebox. Reuse the screws to install
the flue restrictor.
Quadra-Fire · Garnet-T · 7016-127F
Installation of the flue restrictor requires the
With the baffle removed, remove the two screws
Page 31