I. Glass Door Assembly Replacement
Remove the glass door assembly by opening latches at the
bottom front of the appliance, on both the left and right sides.
Lift out and away from the appliance.
Replace with a new glass door assembly.
CAUTION
Handle glass assembly with care.
• Inspect the gasket to ensure it is undamaged.
• Inspect the glass for cracks, chips or
scratches.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
• Replace glass assembly as a complete
assembly.
J. Blower Installation
FROM THE KIT YOU WILL NEED: Blower motor; snap
disc bracket with wire harness; rheostat, rheostat nut; knob;
screws; 1 zip-tie.
TOOLS REQUIRED: #2 Phillips head bit; hand drill; 11/16
in. wrench; and a 5/16 in. wrench.
Attach with 4
screws
Turn off gas supply, (if gas is connected,) and
Figure 8.26
remove rear shield. Remove blower from packaging. Place
blower under appliance. Attach blower from front with 4
screws to blower bracket.
5/16 nut
Install snap disc in bracket. Attach bracket to fi re-
Figure 8.27
box with 5/16 in. wrench.
34
nap isc
Bracket
Quadra-Fire • Topaz • 7009-113 Rev. Q • 6/14
Connect electrical connector to snap disc.
Figure 8.28
Install speed control to switch panel. Attach knob
Figure 8.29
to speed control.
Reinstall rear shield. Connect blower to power
Figure 8.30
supply and turn on gas supply.
NOTE: This blower utilizes a snap disc to control ON and
OFF operation. When the correct temperature is reached,
the blower will automatically turn ON. Use the rheostat knob
to adjust the fan to High or Low to suit your preferences.