Section 1: Listing And Code Approvals; Appliance Certifi Cations; Glass Specifi Cations; Btu Specifi Cations - Quadra-Fire TOPAZ 839-1290 Installation And Operation Maintenance Owner's Manual

Direct vent room heater
Hide thumbs Also See for TOPAZ 839-1290:
Table of Contents

Advertisement

1
Listing and Code Approvals
A. Appliance Certifi cation
MODEL:
Topaz
LABORA-
OMNI Test Laboratories, Inc.
TORY:
061-S-24-5
TYPE:
Direct Vent Gas Heater
STANDARD:
ANSI Z21.88a-2000
UL307b
The product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles" and "Gas Fired Appliances for use at High
Altitudes".
Manufactured Home or Mobile Home installation may occur
only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
B. Glass Specifi cations
This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the unit and to replace any part of the control system and
any gas control which has been under water.
4
ּ
C SA 2.33a-M00
ּ
C AN/CBA 2.17-M91
Quadra-Fire • Topaz • 7009-113 Rev. Q • 6/14
C. BTU Specifi cations
Model
(US or Canada)
Top Vent
Topaz (NG)
Topaz (LP)
ּ
Rear Vent
Topaz (NG)
Topaz (LP)
D. High Altitude Installations
Omni-Test Laboratories listed gas appliances are tested and
approved without requiring changes for elevations from 0 to
2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. If the heating value of the
gas has been reduced, these rules do not apply. To identify
the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
E. Non-Combustible Materials
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750°C, shall be considered non-

combustible materials.

F. Combustible Materials
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.
Maximum Input
Minimum Input
BTU
BTU
39,500
26,500
38,000
30,500
35,000
23,500
27,500
16,500
Orifi ce Size
.125
.073
.113
.063