MANUAL INTRODUCTION

The information in this manual is intended as an installation and commissioning guide for
the vandal resistant two button audio intercom kit. This manual should be read carefully
before the installation commences. Any damage caused to the equipment due to faulty
installations where the information in this manual has not been followed is not the
responsibility of Videx Security Ltd.
VIDEX run free training courses for engineers who are not familiar with the Videx product
range. Technical help is also available on 0191 224 3174 during office hours or via e-mail
tech@videx-security.com.

SYSTEM INTRODUCTION

This kit will enable a caller at an entrance point to signal an occupant in the dwelling by
pressing a call button which will send an electronic call tone to an audio telephone. A
Yellow 'SPEAK' LED will indicate the call has been answered and a two way conversation
can take place, the occupant can release an electric lock release by pressing a button on
the telephone base unit. The kit does not include the electric lock release. A 12V AC
release should be used with this kit (The output for the lock is a dry contact relay so any
other type of lock can be used with an appropriate PSU). If this kit is to be used with a
gate, the dry contact output can be used to trigger the gate control board. DDA features
such as a 'SPEAK' LED, 'DOOR OPEN' LED and reassurance tones are standard on this
kit.
A two code, two relay codelock unit is also incorporated into the door panel to allow users
to gain access using an access code.

SYSTEM COMPONENTS

This kit comprises of a flush or surface vandal resistant door panel, audio telephone and
PSU. Up to a maximum of three telephones can be used on the system to call in parallel.

DOOR PANEL

The vandal resistant door panel will consist of an amplifier module, codelock module, two
buttons, vandal resistant plate, frame and back box.
Dip-Switches
The four way dip-switch bank has the following functions. Please note: dip-switches must
be set before power up. Any changes made when power is on will not take effect until a
power down reset.
Speech time
ON
Switch 1 OFF
Switch 1 ON
1
2
3
4
PAGE 3 of 12
Relay time
1 Minute
Switch 2 OFF
2 Minutes
Switch 3 OFF
Switch 2 OFF
Switch 3 ON
Switch 2 ON
Switch 3 OFF
Switch 2 ON
Switch 3 ON
VR4K-2/CL TECHNICAL MANUAL
Speech live
2 Seconds
Switch 4 OFF
4 Seconds
Switch 4 ON
8 Seconds
(Only possible
on one door
systems)
20 Seconds
Only
when
called
Speech
live
whenever
a handset
is lifted
VER1.1