SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
The slotted end of the tool must engage with
the pin in the endshaft on the slideout gear
assembly. See arrow in close-up detail.
Crank the ratchet wrench clockwise to retract
the room. The tool will extend nearly a foot
out of the bed base at first, but will be drawn
into the bed base as the room is retracted. This
is a slow process that will take some time and
quite a few turns of the wrench.
As the room retracts, the bed base will move
away from the gear endshaft, which will
eventually cause the tool to lose contact with
the shaft. When this happens, you must raise
the bed, remove the access cover to access the
gear endshaft, and continue using the wrench
and hex shaft only as shown.

GENERAL SLIDEOUT CARE

Wipe outer seals occasionally with talc or 303
brand protectant for smooth quiet operation.
Clean the floors inside before retracting the
room to avoid vinyl flooring scratches or
carpet pile snags.
See your authorized dealer for regular
maintenance and service of the slideout
mechanism.
10-16
WARNING
Never check for hydraulic fluid leaks
using your hands and/or any other body
part. The leaking fluid is under pressure
and is capable of cutting and penetrating
your skin, resulting in severe injury.

LEVELING SYSTEM

–If Equipped
The leveling system makes selecting a parking
site easier and faster by reducing the effect of
uneven ground.
Hydraulic jacks raise the affected low corners
of the coach to make leveling "set up" faster and
easier for you.
The hydraulic leveling system control pad is
located on the lower left side of the dash or
driver's sidewall panel. Your coach may be
equipped with one of the panels shown.
®
HWH
Leveling Control Pad