15
. IGNITION SYSTEM
CDI UNIT INSPECTION
Remove the three battery cover screws.
Disconnect the CDI coupler and remove the
CDI unit.
Measure the resistance between the terminals
using the electric tester.
*
• Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
• Use a Sanwa Electric Tester or Kowa
Electric Tester.
• In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The needle
will then remain at "∞" unless the
condenser is discharged.
Probe⊕
Black
Yellow
(-)Probe
Black
Black/
30
80
~
Yellow
Blue/
100
250
~
Yellow
Green
10
30
~
15-3
Unit: KΩ
Black/
Blue/
Green
Yellow
∞
~ ∞
1K
10
60
~
150
400
5
15
~
~
∞
40
90
~
∞
60
200
~
CDI Unit
Black
Black/
Blue/
Green
Yellow
Yellow
AGILITY 125