Float Chamber; Agility 125 - KYMCO Agility 125 Service Manual

Hide thumbs Also See for Agility 125:
Table of Contents

Advertisement

5
. FUEL SYSTEM

FLOAT CHAMBER

DISASSEMBLY
Remove the three float chamber screws and
the float chamber.
Loosen the float pin screw.
Remove the float pin, float and float valve.
Remove the main jet, needle jet holder,
needle jet, slow jet and pilot screw.
• Be careful not to damage the fuel jets
and pilot screw.
• Before removing, turn the pilot screw
in and carefully count the number of
turns until it seats lightly and then
make a note of this.
• Do not force the pilot screw against its
seat to avoid seat damage.
Clean the removed fuel jets with detergent
oil and blow them open with compressed
air.
Blow compressed air through all passages
of the carburetor body.
Screws
Float Chamber
Float
Float Pin
Needle Jet Holder
Pilot Screw
Needle Jet

AGILITY 125

Float Valve
Slow Jet
Main Jet
5-8