Gate Operator System Overview continued
MAX BC-7 Battery Module
2
1
MAX MC-100 Motor Controller
MC-100
ERD
JOG
Sensitivity
Motor Controller
A
LEFT
D
MOTOR OVERLOAD
ERD
Max
B
Min
Sensitivity
C
External Open/Close
Key Switch,
Dual Gate Operators
See page 32.
24V ONLY
Photocell
Power.
To Matrix 1
24V
RS-485
www.max.us.com
16
Wiring operator
A
U S
i n
d e
M a
C - 7
X B
l e
d u
M o
M A
r y
t t e
B a
C - 7
6
X B
d u l
e
M A
M o
r y
t t e
B a
I N
r y
t t e
4
B a
o r
E r r
I N
S T
r y
T E
t t e
g e
r y
B a
o r
t t e
l t a
E r r
c e
B a
V o
T
p l a
T E S
r y
7
F
R e
r y
r y
t t e
g e
t t e
t t e
l t a
B a
1 / 2
F
B a
c e
B a
/ O F
V o
p l a
O N
R e
r y
F
r y
r y
E
t t e
t t e
t t e
F
B a
B a
/ O F
B a
1 / 2
O N
r y
t t e
5
E
B a
3
G
I
K
JOG
Matrix
UL
RIGHT
Edge 1
On Line
Entrap
F
Power
E
Limit SW
Edge 2
Photo
M
INPUTS
On Line
Cell
H
J
L
Photocell (N.O.)
GND
OPENING Cycle
Edge 1
(N.O.)
GND
Edge 2
(N.O.)
GND
Sensing Edges
ALARM
LIMIT
BATTERY
MOTOR
POWER IN
MOTOR
SWITCH
PACK
INPUTS
1
BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
2
POWER/SOLAR IN Port: MAX PS-24 Power Supply connection.
3
Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
4
ON/OFF Battery Button:
IMPORTANT:
Battery power automatically turns ON when MAX PS-24 Power
Supply AC POWER Switch is turned ON.
To turn OFF ALL POWER to operator:
1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
5
Replace Battery LED: Replace battery when lit.
6
TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
7
Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plugs are correctly installed and there is no damaged or
loose wires.
A
MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
B
ERD LED: ERD sensor has been activated when lit.
C
ERD Sensitivity Knob: Changes sensitivity of ERD sensor.
D
ERD Sensitivity LED: MAX sensitivity reached when lit.
E
Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
Photocells
stop gate).
WARNING:
ONLY.
F
INPUTS:
Jog LT/RT: Connects to External Open/Close Key Switch. Connect a
single key switch to control dual gate operators, See page 32.
GND: Low Voltage Common connection.
Edge 1: Connects to a Sensing Edge. Multiple sensing edges can be
connected.
Edge 2: Connects to a second Sensing Edge. Multiple sensing edges can
be connected.
PHOTOCELL: Connects to a UL 325 Standard OPENING Cycle photocell
ONLY. Multiple OPENING Cycle photocells can be connected.
Matrix On Line LED: Gate operator is successfully communicating with
G
Matrix 1 when lit.
H
Limit SW On Line LED: Limit Switch Box is successfully communicating
with MC-100 Motor Controller when lit.
I
Edge 1 LED: Reversing Edge 1 input has been activated when lit.
Edge 2 LED: Reversing Edge 2 input has been activated when lit.
J
UL Entrap LED: Edge1/Edge2/Photocell input has been activated when lit.
K
Photocell LED: Photocell input has been activated when lit.
L
Power LED: Low voltage power is connected when lit.
M
DUAL GATE OPERATORS NOTE: Connect EACH photocell/reverse
edge to the corresponding gate operator. See page 8.
Avoid moving arm while using Jog buttons.
Need help?
Do you have a question about the MAX MEGATRON 2500 and is the answer not in the manual?
Questions and answers