Maximum Controls MAX MEGATRON 2500 Installation And Owner's Manual page 18

High traffic commercial brushless dc high profile swing gate operator
Table of Contents

Advertisement

Gate Operator System Overview continued
MAX BC-7 Battery Module
2
1
MAX MC-100 Motor Controller
MC-100
ERD
JOG
Sensitivity
Motor Controller
A
LEFT
D
MOTOR OVERLOAD
ERD
Max
B
Min
Sensitivity
C
External Open/Close
Key Switch,
Dual Gate Operators
See page 32.
24V ONLY
Photocell
Power.
To Matrix 1
24V
RS-485
www.max.us.com
16
Wiring operator
A
U S
i n
d e
M a
C - 7
X B
l e
d u
M o
M A
r y
t t e
B a
C - 7
6
X B
d u l
e
M A
M o
r y
t t e
B a
I N
r y
t t e
4
B a
o r
E r r
I N
S T
r y
T E
t t e
g e
r y
B a
o r
t t e
l t a
E r r
c e
B a
V o
T
p l a
T E S
r y
7
F
R e
r y
r y
t t e
g e
t t e
t t e
l t a
B a
1 / 2
F
B a
c e
B a
/ O F
V o
p l a
O N
R e
r y
F
r y
r y
E
t t e
t t e
t t e
F
B a
B a
/ O F
B a
1 / 2
O N
r y
t t e
5
E
B a
3
G
I
K
JOG
Matrix
UL
RIGHT
Edge 1
On Line
Entrap
F
Power
E
Limit SW
Edge 2
Photo
M
INPUTS
On Line
Cell
H
J
L
Photocell (N.O.)
GND
OPENING Cycle
Edge 1
(N.O.)
GND
Edge 2
(N.O.)
GND
Sensing Edges
ALARM
LIMIT
BATTERY
MOTOR
POWER IN
MOTOR
SWITCH
PACK
INPUTS
1
BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
2
POWER/SOLAR IN Port: MAX PS-24 Power Supply connection.
3
Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
4
ON/OFF Battery Button:
IMPORTANT:
Battery power automatically turns ON when MAX PS-24 Power
Supply AC POWER Switch is turned ON.
To turn OFF ALL POWER to operator:
1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
5
Replace Battery LED: Replace battery when lit.
6
TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
7
Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plugs are correctly installed and there is no damaged or
loose wires.
A
MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
B
ERD LED: ERD sensor has been activated when lit.
C
ERD Sensitivity Knob: Changes sensitivity of ERD sensor.
D
ERD Sensitivity LED: MAX sensitivity reached when lit.
E
Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
Photocells
stop gate).
WARNING:
ONLY.
F
INPUTS:
Jog LT/RT: Connects to External Open/Close Key Switch. Connect a
single key switch to control dual gate operators, See page 32.
GND: Low Voltage Common connection.
Edge 1: Connects to a Sensing Edge. Multiple sensing edges can be
connected.
Edge 2: Connects to a second Sensing Edge. Multiple sensing edges can
be connected.
PHOTOCELL: Connects to a UL 325 Standard OPENING Cycle photocell
ONLY. Multiple OPENING Cycle photocells can be connected.
Matrix On Line LED: Gate operator is successfully communicating with
G
Matrix 1 when lit.
H
Limit SW On Line LED: Limit Switch Box is successfully communicating
with MC-100 Motor Controller when lit.
I
Edge 1 LED: Reversing Edge 1 input has been activated when lit.
Edge 2 LED: Reversing Edge 2 input has been activated when lit.
J
UL Entrap LED: Edge1/Edge2/Photocell input has been activated when lit.
K
Photocell LED: Photocell input has been activated when lit.
L
Power LED: Low voltage power is connected when lit.
M
DUAL GATE OPERATORS NOTE: Connect EACH photocell/reverse
edge to the corresponding gate operator. See page 8.
Avoid moving arm while using Jog buttons.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAX MEGATRON 2500 and is the answer not in the manual?

Questions and answers

Table of Contents