Fixing To The Wall - Ferroli SYS 10-23 Installation, Maintenance And User Instructions

Wall-hung, gas-fired, system boiler, for central heating
Table of Contents

Advertisement

A

Fixing to the wall

Select suitable mounting position for boiler, using the template mark flue outlet and boiler mounting
points. Drill two 10mm holes 90mm deep to accept the wall plugs, fit wall plugs. Fit two special wall
plugs on the wall as described in the fig. 3. Fasten the wall bracket to the wall using an antitheft
nut on the right side and a standard nut (M8) on the left side. Mount the boiler on the wall bracket
and fix using an antitheft nut on the left side and a standard nut (M8) on the right side. Using a core
drill cut a 118mm diameter hole for the flue.
8
Ø118
A
fi g. 3
SYS 10-23
Table 3
Minimum
A
30 mm
B
200 mm
C
280 mm
15 mm
D
(from opening panels)
fi g. 2
Recommended
150 mm
300 mm
300 mm
> 600 mm