Water Connections - Ferroli SYS 10-23 Installation, Maintenance And User Instructions

Wall-hung, gas-fired, system boiler, for central heating
Table of Contents

Advertisement

SYS 10-23

2.3 Water connections

The heat capacity of the appliance should be established in advance by calculating the heating
requirements of the building according to the standards in force. For correct operation and long-life
of the boiler, the hydraulic system must be suitably proportioned and always fitted with all the
accessories that guarantee regular operation.
In the case where the central heating outlet and inlet pipes follow paths whereby, at some points,
pockets of air may form, air vent valves should be installed at such points.
In addition, a drain device should be installed at the lowest point in the system, to allow
complete draining.
If the boiler is installed at a lower level than the system, a flow-return valve should be fitted to prevent
the natural circulation of water in the system.
The temperature differential between the outlet and the inlet
of the boiler should not exceed 20°C.
Do not use the water pipes as the earth for electrical
appliances.
Before installation, carefully clean all the pipes in the system to
remove any residues or impurities that may affect the correct
operation of the appliance.
Make the connections to the corresponding fittings, as
shown in fig. 4.
Key
1
Central heating outlet, 3/4"
2
Gas inlet, 1/2"
3
Central heating inlet, 3/4"
It is recommended to fit isolation valves between the boiler and the central heating system; these allow
the boiler to be isolated from the heating system, if necessary.
The discharge of any safety valves must be routed to outside dicharging to ground level
100 mm from the floor so as not to create a danger to anyone passing. The manufacturer
of the boiler will not be held liable if this warning is not heeded, and the discharge valve
intervenes and floods the room.
Make the connections to the boiler in a way that its internal tubing is not subject to stress.
36
155
1
fi g. 4
155
54
2
3
9