Technical Data Table - Ferroli SYS 10-23 Installation, Maintenance And User Instructions

Wall-hung, gas-fired, system boiler, for central heating
Table of Contents

Advertisement

SYS 10-23

4.4 Technical data table

Output
Nominal Heat Input (Net)
Nominal Heat Output
Gas supply
Main injectors, Natural Gas (G20)
Supply pressure, Natural Gas (G20)
Burner pressure, Natural Gas (G20)
Natural gas rate (G20)
Main injectors, LPG (G31)
Supply pressure, LPG (G31)
Burner pressure, LPG (G31)
LPG gas rate (G31)
Central heating
Maximum central heating operating temperature
Maximum central heating operating pressure
Safety valve
Minimum central heating operating pressure
Expansion vessel capacity
Expansion vessel pre-fill pressure
Hot water capacity
Dimensions, weights, fittings
Height
Width
Depth
Weight with packaging
Gas system fittings
System filling fittings
Central heating system fittings
Power supply
Max Power Absorbed
Power supply voltage/frequency
Index of protection
Pmax
Pmin
kW
25,8
kW
23,3
Pmax
mm
12 x 1.3
mbar
20,0
mbar
11,8
nm 3 /h
2,73
mm
12 x 0.77
mbar
36,0
mbar
36,0
kg/h
2,00
°C
90
bar
3
bar
3
bar
0,8
litres
7
bar
1
litres
1,5
mm
720
mm
400
mm
370
kg
35
inches
1/2"
inches
1/2"
inches
3/4"
W
125
V/Hz
230/50
IP
X4D
11,2
9,7
Pmin
2,5
1,19
7,0
0,87
31

Advertisement