Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control installation, servicing and user instructions (48 pages)
Gas combination boiler for central heating and hot water production, wall mounted, copper heat exchanger, fan assisted, room sealed, electronic flame ignition and control installation, service and user instructions (52 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (48 pages)
Coper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (44 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (68 pages)
Page 1
IT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN RO - INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE HU - HASZNÁLATI, BESZERELÉSI ÉS KARBANTARTÁSI UTASÍTÁS SK - NÁVOD NA POUŽITIE A ÚDRŽBU...
Open the bottom door and remove any ash from the combustion chamber. Close 2.1 Introduction the bottom door. The SFL is a new cast-iron boiler for heating, using solid fuels (wood and coke), or pellets • Turn thermostatic regulator knob 6 to the required temperature value.
Connect the outlet to the valve. fig. 3 - Safety heat exchanger connection In pellet use only (with burners FERROLI“SUN P7” - “SUN P12”), as an alter- native to the safety coil it is possible to use the "Thermostatic safety kit" code 033001X0.
Page 4
For installation, refer to the instructions contained in the kit. Instructions for installing the pellet burner SUN P7 - P12 in the boiler SFL Insert the temperature probe “C” in the special hole, making sure to run the cable “ E”...
Page 5
3.5 Installation Safety thermostat kit (optional) only with 14-pole terminal block A “safety thermostat” kit is available on request as an alternative to the “Safety coil” to be used with the boiler working with pellets. For installation, carry out the following instructions. •...
Qualified Personnel (meeting the professional technical re- quirements prescribed by the current regulations). FERROLI declines any liability for damage and/or injury caused by unqualified and un- authorised persons tampering with the unit. 4.1 Adjustments Secondary air adjustment The secondary air control device must be set during the commissioning stage.
Then remove any soot deposited in the ashpan. Also make sure the fume exhaust pipes and flue are clean and perfectly tight. Data Unit SFL 3 SFL 4 SFL 5 SFL 6 SFL 7...
Chairman and Legal Representative Knight of Labour Dante Ferroli Déclaration de conformité Le constructeur : FERROLI S.p.A. Adresse : Via Ritonda 78/a - 37047 San Bonifacio VR déclare que cet appareil est conforme aux directives CEE ci-dessous : • Directive basse tension •...
Megfelelségi nyilatkozat A gyártó: FERROLI S.p.A. Cím: Via Ritonda 78/a - 37047 San Bonifacio VR kijelenti, hogy a jelen berendezés megfelel az alábbi EGK irányelveknek: • sz. irányelv a kisfeszültségrl • sz. irányelv az elektromágneses kompatibilitásról • 97/23 sz. irányelv a nyomástartó berendezésekrl (csak fatüzelés) •...