Operation

Dimmer Profiles

Curve Settings

Control Panel
Lock

Passcode

Program Upload

-12-
This setting determines how fast the output of the COLORado™ 2-Quad Zoom IP changes
when you modify the values of the red, green, blue, white, and dimmer faders. This setting
provides four different options to simulate the dimming curve of an incandescent lighting
product.
1. Go to the SET main level.
2. Select DIM.
3. Select a dimmer curve (OFF, DIM1., DIM2., DIM3., or DIM4.).
OFF:
The output is proportional (linear) to the dimmer and RGBW channel values.
DIM1.–4.:
The output follows the dimmer and RGBW channel values based on the
corresponding dimmer curve, DIM1. being the fastest and DIM4. the slowest.
This setting allows you to select the dimmer curve shape using the red, green, blue, white, and
dimmer faders.
1. Go to the SET main level.
2. Select CURV.
3. Select a dimmer curve (OFF, CV1, CV2, or CV3).
OFF:
The output is proportional (linear) to the dimmer and RGBW channel values.
CV1–3:
The output follows the dimmer and RGBW channel values based on the
corresponding dimmer curve, CV1 being the fastest and CV3 the slowest.
For optimum control of the 16-bit dimming channels in the TR16 and STD.Y personalities,
be sure that both dimming curves in SET > DIM and SET > CURV are set to OFF.
This setting enables you to activate or disable the control panel lock, which keeps non-
authorized personnel from changing the product's settings.
1. Go to the KEY main level.
2. Select ON or OFF.
When the control panel lock is active, the product will prompt you to enter the passcode
after 30 seconds of control panel inactivity or after turning on the product.
After being prompted to enter the passcode:
·
Press <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>.
This option allows you to copy the custom programs of one COLORado™ 2-Quad Zoom IP onto
other COLORado™ 2-Quad Zoom IPs by using the Master/Slave mode.
1. Configure and connect the products in a Master/Slave arrangement, where the master has
the custom programs you want to transfer to the slaves.
2. From the master, go to the SET main level.
3. Select UPLD, press <ENTER>.
4. Enter the master access passcode as shown in Passcode.
5. When SEND shows, press <ENTER> to start the upload.
6. Wait for the upload process to finish (the display will show END) before continuing or
turning the products off.
The master and slaves will provide the status of the process by lighting up as follows:
·
Yellow indicates that the upload process is running.
·
Green indicates that the upload process completed successfully.
·
Red indicates that the upload process failed due to an error. Recheck all cable
connections and restart the process. If the issue persists, contact Chauvet Technical
Support.
DO NOT upload the data from a COLORado™ 2-Quad Zoom IP to a different product. The
other product may become inoperative.