TROUBLESHOOTING - FR110
Information displayed
(
items 1, 3 and 4 in Fig.
Text
Fault 11
System configuration: new BUS device
New ISM detected. Power up all ISMs
simultaneously and start automatic
system configuration.
Fault 12
System configuration: BUS device
missing
ISM1 not detected. Check connection.
Fault 13
System configuration: BUS device
changed or replaced
Check system configuration for DHW or
start automatic system configuration.
Fault 13
System configuration: BUS device
changed or replaced
Check system configuration for heating
circuit x and connections on IPM for
heating circuit x.
Fault 14
System configuration: incompatible
BUS device
DHW controlled by boiler. IPM control
of DHW has no effect.
Fault 14
System configuration: incompatible
BUS device
IPM for cylinder must be set to
identification 3 or higher.
Fault 19
Unable to save parameter settings
Fault 33
Temperature sensors incorrectly
connected
Fault 40
Temperature sensor T1 on collector
group 1 faulty
Fault 41
Temperature sensor T2 at bottom of
solar cylinder faulty
Tab. 32
64
Supplied By www.heating spares.co Tel. 0161 620 6677
)
17
Code Cause
131
New ISM detected.
132
170
HLC has tripped or is faulty.
171
ISM1 no longer detected despite
having been configured.
157
BUS device changed or replaced.
159
BUS device changed or replaced.
117
Incompatible BUS device:
118
Incompatible BUS device:
119
202
BUS device is configured but not
available at present.
22
A temperature sensor is connected
to the IUM.
101
Short circuit on the sensor lead
(T
).
1
102
Break in the sensor lead (T
103
Short circuit on the sensor lead
(T
).
2
104
Break in the sensor lead (T
Remedy
Power up all ISMs
simultaneously and start
automatic system configuration.
Check HLC.
Check solar parameter T2
Is thermal disinfection active?
Check connection.
Check system configuration for
hot water system or start
automatic system configuration.
Check system configuration for
heating circuit x.
Identify incompatible BUS
device and remove from the
system.
Set IPM for cylinder to coding 3
or higher.
Check system layout, check
system configuration, modify if
necessary and set parameter
again.
Remove the temperature sensor
and insert a coding plug if
necessary.
Check temperature sensor (T
and replace if necessary.
).
1
Check temperature sensor (T
and replace if necessary.
).
2