Worcester CDi Combi N.G Service Booklet page 9

Floor mounted and wall hung rsf gas fired condensing boilers
Table of Contents

Advertisement

Fig. 6
Front of the control panel
1
Flame viewing window
2
Ignition electrode and flame sense electrode
3
Heat exchanger
4
Overheat thermostat
5
Access point for cleaning heat exchanger
6
Condensate hose
7
Drain point
8
Trap / syphon outlet connection (22 mm plastic pipe)
9
CH return
10
Gas inlet connection 22 mm compression
11
Cover for external wiring connections
12
Control panel in service position
13
Access cover for transformer & PCB
14
CH flow
15
Inlet pressure test point
16
Trap / syphon
17
Gas valve
18
Air / gas adjustment screw
19
Testing point for fan pressure
20
Fan
21
Primary sensor
22
Auto air vent
23
Removable top case panel for servicing
24
Display
25
Fault reset button
26
Non functional on CDi Regular
27
Holiday button
28
Mains On/off indicator/diagnostic light (blue)
29
CH temperature control
30
Central heating boost button
31
Service button
32
Burner on indicator light (green)
33
Master switch on/off
8 716 115 748 (2009/09)
Supplied By www.heating spares.co Tel. 0161 620 6677
33
32
31
30
; ?
29
28
24
25
26
27
8716115748-02.1Wo
LAYOUT OF BOILER
9