RECTIFYING FAULTS
FA
and RESET button and fault indicator LED are flashing.
After appliance switches off flame is detected
Check
1.
Is the condensate trap blocked?
2.
Electrode assembly defective?
B Switch OFF the appliance.
B Remove electrode assembly.
Electrode assembly burnt out?
3.
Problem with flue?
B Check CO
level in combustion air
2
in the flue (with outer casing fit-
ted).
Is CO
level above 0.2%?
2
4.
Is the gas valve damaged?
5.
B Switch OFF the appliance.
B Disconnect the boiler power con-
nection.
B Check if the 20-pin connector
lead assembly is damaged.
Tab. 28 FA Error codes
50
Supplied By www.heating spares.co Tel. 0161 620 6677
Action
yes:
B Switch OFF the appliance.
B Clean out condensate trap discharge pipe.
B Switch ON the appliance.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
FA? go to 2
no:
go to 2
yes:
B Replace electrode assembly.
B Switch ON the appliance.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
FA? go to 3
no:
go to 3
yes:
There are flue gases in the combustion air.
B Check flue, clean if necessary.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
FA? go to 4
no:
go to 4
yes:
B Switch OFF the appliance.
B Disconnect the boiler power connection.
B Turn off gas valve.
B Change the gas valve.
B Open the gas valve.
B Reconnect the appliance power connection.
B Switch ON the appliance.
B Check appliance for leaks.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
FA? go to 5
no:
go to 5
B Change the connector lead assembly.
B Reconnect the appliance power connection.
B Switch ON the appliance.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
FA? go to 6
8 716 115 748 (2009/09)