Centurion CP70R5 User Manual page 22

Table of Contents

Advertisement

SYMPTOM
Gate opens on its own.
Radio transmitter has poor
range.
Master gate opens to pedes-
trian and closes.
Courtesy light does not oper-
ate.
CAUSE
Origin position has been
shifted.
Permanent input on one of
t h e t r i g g e r l i n e s t o t h e
controller.
Faulty trigger line cables.
Transmitter battery flat.
R a d i o r e c e i v e r c a n n o t
receive transmitter signal
properly.
K e y - s w i t c h u s e d f o r
activating pedestrian facility
is faulty - where applicable.
Light fuse blown.
Page 22
ACTION
Consult your installer if the
problem persists.
Make sure that nobody has
accidently used the origin
adjustment tool to release
the manual override. Consult
your installer should this be
suspected.
Check that the RED LED's
adjacent each trigger input
on the controller (TRG, FRX,
PED) are OFF and only
switch ON when that input is
activated.
Consult your installer.
Check that the fault only
o c c u r s w i t h o n e o f t h e
transmitters. Replace the
battery.
Receiver must be mounted in
an elevated position, housed
i n a w e a t h e r p r o o f, n o n
ferrous enclosure.
Make sure that the aerial is
straight.
Consult your installer.
Check for corrosion of the
wire terminations behind the
key-switch. Consult your
installer should the problem
persist.
Replace fuse - 220V 3A fast
blow. Size 5x20mm.
CAUTION - 220V, make
sure supply to system is
isolated
Check that the lamp load
does not exceed 500W.
Check the bulb and replace if
necessary. Make sure that
the bulb is making good
electrical contact in its
holder.
Consult your installer should
the problem persist.