ClimateMaster Tranquility 30 TE026 Installation, Operation & Maintenance Instructions Manual

ClimateMaster Tranquility 30 TE026 Installation, Operation & Maintenance Instructions Manual

Digital (te) series iom

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tranquility 30 TE026 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ClimateMaster Tranquility 30 TE026

  • Page 1: Table Of Contents

    ® Tranquility 30 Digital (TE) Series IOM 97B0045N04 Residential Horizontal, Vertical & Downfl ow Packaged Geothermal Heat Pumps Installation, Operation & Maintenance Instructions Rev.: 29 May, 2015J Table of Contents Model Nomenclature Electrical—Thermostat Wiring Storage Wiring Diagrams 31–34 Pre-Installation ECM Blower Control Vertical Installation Blower Data Horizontal Installation...
  • Page 2 This page was intentionally left blank.
  • Page 3: Model Nomenclature

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Model Nomenclature: General Overview 4 5 6 0 2 6 0 2 C L T STANDARD SERIES S = Standard TE = Tranquility...
  • Page 4: Storage

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J General Information Inspection CAUTION! Upon receipt of the equipment, carefully check the shipment against the bill of lading. Make sure all units and accessories CAUTION! DO NOT store or install units in corrosive have been received.
  • Page 5: Vertical Installation

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Vertical Installation Figure 2: Service Access Vertical Unit Location Packaged units are not designed for outdoor installation. Legend Locate the unit in an INDOOR area that allows enough space CCP=Control/Compressor Access Panel...
  • Page 6: Horizontal Installation

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Horizontal Installation Horizontal Unit Location Mounting Horizontal Units Packaged units are not designed for outdoor installation. Horizontal units have hanger kits pre-installed from the Locate the unit in an INDOOR area that allows enough space factory as shown in Figure 4.
  • Page 7 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Horizontal Installation Figure 6a: Typical Closed Loop Horizontal Unit Installation (with Internal Flow Controller) Water 3/8" [10mm] threaded rods (by others) Pressure Ports Flexible Duct...
  • Page 8 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Horizontal Installation Field Conversion of Air Discharge Figure 7: Left Return Side to Back Overview - Horizontal units can be fi eld converted Remove Screws Water Connection End...
  • Page 9: Condensate And Water Connection

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Condensate and Water Connection Condensate Piping Water Connections Pitch the unit toward the drain as shown in Figure 5 to Residential models utilize swivel piping fi...
  • Page 10: Vflow ™ Heat Pump

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J vFlow Heat Pump Applications Overview ™ vFlow ™ is a revolutionary new, intelligent, and effi cient way to Figure 11a: Typical Closed-Loop Application (with circulate water (or water plus antifreeze) using INTERNAL, Internal Flow Controller Shown)
  • Page 11: Closed Loop Heat Pump Applications

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Closed Loop Heat Pump Applications with Internal Flow Controller Units with internal fl ow control come with a built-in variable Figure 12: Internal Flow Controller speed pump, an expansion tank, fl...
  • Page 12: Closed Loop Heat Pump Applications

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Closed Loop Heat Pump Applications with Internal Flow Controller Figure 13: Magna Geo 25-140 High Head Variable Pump Performance GPM Head (ft) Magna Geo 25-140 Pump Curve 44.7...
  • Page 13: Flushing The Earth Loop

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Flushing the Earth Loop Once piping is completed between the unit and the ground WARNING! loop, fi nal purging and charging of the loop is needed. WARNING! Disconnect electrical power source to prevent A fl...
  • Page 14 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Flushing the Earth Loop Figure 15b: Valve Position B - Unit Fill / Flush NOTICE: Actual fl ushing time require will vary for each installation due to piping length, confi...
  • Page 15: Flushing The Earth Loop

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Flushing the Earth Loop Loop static pressure will fl uctuate with the seasons and NOTICE: It is recommended to run the unit in the cooling, pressures will be higher in the winter months than during then heating mode for 15-20 minutes each to ‘temper’...
  • Page 16: Multiple Unit Piping And Flushing

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Multiple Unit Piping and Flushing Often projects require more than one heat pump. Where Table 2: Internal 3-Way Flushing Valve Data possible, it makes sense for multiple units to share a common Flushing Straight...
  • Page 17 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Multiple Unit Piping and Flushing Multiple Units with Internal Flow Controllers The simplest multiple unit system is one with two (or more) units utilizing internal Flow Controllers with no external pumps or fl...
  • Page 18: Multiple Unit Piping And Flushing

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Multiple Unit Piping and Flushing Figure 16b: Multiple Units with Internal Flow Controllers and External Flushing Valves Ground Loop Size for Heat Pump Shut-Off Valve...
  • Page 19: Ground Loop Heat Pump Applications

    30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Ground Loop Heat Pump Applications Contact your ClimateMaster distributor if you have any Antifreeze Selection - General In areas where minimum entering loop temperatures drop questions as to antifreeze selection.
  • Page 20: Low Temperature Cutout Selection

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Ground Loop Heat Pump Applications 10 gallons [37.9 liters] total. If more than one tankful is Chart 1a: Methanol Specifi...
  • Page 21: Closed Loop-External Central

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Closed Loop - External Central Pumping Applications Figure 18: Typical Closed Loop with Central Pumping Application (with Internal Modulating Motorized Valve Shown) To Thermostat Internal Motorized Modulating Valve...
  • Page 22: Open Loop Or Ground-Water

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Open Loop or Ground-Water Heat Pump Applications Open Loop - Ground Water Systems Figure 20: Typical Open Loop/Well Application Typical open loop piping is shown in Figure 20.
  • Page 23: Open Loop Or Ground-Water

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Open Loop or Ground-Water Heat Pump Applications Pressure Tank and Pump Water Coil Low Temperature Limit Setting Use a closed, bladder-type pressure tank to minimize For all open loop systems the 30°F [-1.1°C] LT1 setting mineral formation due to air exposure.
  • Page 24: Water Quality Requirements

    20 mesh] size. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. The water should be evaluated by an Rev.: 5/6/2014 S independent testing facility comparing to this Table and when properties are outside of these requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water.
  • Page 25: Hot Water Generator

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Hot Water Generator The HWG (Hot Water Generator) or desuperheater option It is always advisable to use water softening equipment on provides considerable operating cost savings by utilizing domestic water systems to reduce the scaling potential and heat energy from the compressor discharge line to help...
  • Page 26 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Hot Water Generator Figure 23: Anti-Scald Valve Piping Connections Installation ANTI-SCALD The HWG is controlled by two sensors and the DXM2 micro- COLD WATER VALVE PIPING processor control.
  • Page 27 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Hot Water Generator 4. Inspect all work for leaks. WARNING! 5. Before restoring power or fuel supply to the water heater, adjust the temperature setting on the tank thermostat(s) WARNING! The HWG pump Is fully wired from the to insure maximum utilization of the heat available from...
  • Page 28: Electrical-Line Voltage

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Electrical - Line Voltage Electrical - Line Voltage WARNING! All fi eld installed wiring, including electrical ground, must comply with the National Electrical Code as well as all WARNING! To avoid possible injury or death due to applicable local codes.
  • Page 29: Electrical-Low Voltage Wiring

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Electrical - Low Voltage Wiring Figure 26: Tranquility Low Voltage Field Wiring Table 9: Accessory Relay 2 Confi guration DIP 2.4 DIP 2.5 DIP 2.6...
  • Page 30: Electrical-Thermostat Wiring

    Thermostat DXM2 Board CAUTION! Compressor Compressor Stage 2 CAUTION! Refrigerant pressure activated water regulating Auxiliary Heat valves should never be used with ClimateMaster Dehumidification equipment. Reversing Valve CAUTION! 24Vac Hot 24Vac Common CAUTION! If communicating thermostat is not installed, a Fault LED communicating service tool must be used to confi...
  • Page 31: Wiring Diagrams

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N60 Part 1 of 2 This diagram includes typical wiring details but is not applicable to all units. For specifi c unit wiring, refer to the diagram or the units’...
  • Page 32 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N60 Part 2 of 2 G e o t h e r m a l H e a t i n g a n d C o o l i n g...
  • Page 33 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Wiring Diagram with Motorized Modulating Water Valve - 96B0005N62 - Part 1 of 2 This diagram includes typical wiring details but is not applicable to all units. For specifi c unit wiring, refer to the diagram or the units’...
  • Page 34: Wiring Diagrams

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Wiring Diagram with Motorized Modulating Water Valve - 96B0005N62 - Part 2 of 2 G e o t h e r m a l H e a t i n g a n d C o o l i n g...
  • Page 35: Ecm Blower Control

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J ECM Blower Control The ECM fan is controlled directly by the DXM2 control board Special Note for AHRI Testing: To achieve rated airfl ow for that converts thermostat inputs and CFM settings to signals AHRI testing purposes, it is necessary to change the CFM used by the ECM motor controller.
  • Page 36: Blower Data

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J ECM Blower Performance Data ® Table 10: Tranquility 30 (TE) Series ECM Blower Performance Data Table Airfl...
  • Page 37: Dxm2 Controls

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Controls DXM2 iGate Controller DXM2 is the next generation in DIP Switches – There’s no need to change the DIP switches ™...
  • Page 38: Dxm2 Layout And Connection

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Layout and Connections Figure 31: LT1 Limit Setting Low Water Temperature Cutout Selection The DXM2 control allows the fi eld selection of low water (or water-antifreeze solution) temperature limit by clipping jumper JW3, which changes the fault cutout temperature associated with thermistor LT1.
  • Page 39: Unit Commissioning And Operating Conditions

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Commissioning And Operating Conditions Operating Limits Environment – Units are designed for indoor installation only. Never install units in areas subject to freezing or where humidity levels could cause cabinet condensation (such as unconditioned spaces subject to 100% outside air).
  • Page 40: Unit Start-Up And Operating Conditions

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Start-Up and Operating Conditions Unit and System Checkout CAUTION! BEFORE POWERING SYSTEM, please check the following: CAUTION! Verify that ALL water valves are open and UNIT CHECKOUT allow water fl...
  • Page 41: Unit Start-Up Procedure

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Start-Up Procedure a. Go into Manual Mode activate Y1, and Y2 for SERVICE MODE Heating. Also manually increase CFM until desired MANUAL OPERATION heating CFM is achieved.
  • Page 42: Coax Pressure Drop Table

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Start-Up Procedure If performance during any mode appears abnormal, refer to the DXM2 section or troubleshooting section of this manual. NOTE: To obtain maximum performance, the air coil should be cleaned before start-up.
  • Page 43 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Operating Conditions - TE Table 15: TE Series Typical Unit Operating Pressures and Temperatures TE026 Full Load Cooling - without HWG active Full Load Heating - without HWG active Entering...
  • Page 44 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Unit Operating Conditions - TE Table 15: TE Series Typical Unit Operating Pressures and Temperatures: Continued TE064 Full Load Cooling - without HWG active Full Load Heating - without HWG active...
  • Page 45: Performance Data

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Table 17a: Performance Data — Tranquility 30 Digital - Model 026 ® Full Load - with vFlow ™...
  • Page 46 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Table 17b: Performance Data — Tranquility 30 Digital - Model - 038 ® Full Load - with vFlow ™...
  • Page 47 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Table 17c: Performance Data — Tranquility 30 Digital - Model - 049 ® Full Load - with vFlow ™...
  • Page 48 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Table 17d: Performance Data — Tranquility 30 Digital - Model - 064 ® Full Load - with vFlow ™...
  • Page 49: Performance Data

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Table 17e: Performance Data — Tranquility 30 Digital - Model - 072 ® Full Load - with vFlow ™...
  • Page 50: Preventive Maintenance

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Preventive Maintenance Water Coil Maintenance Condensate Drain (Direct ground water applications only) - If the system is In areas where airborne bacteria may produce a “slimy”...
  • Page 51: Troubleshooting

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Troubleshooting General Table 18: Nominal resistance at various temperatures If operational diffi culties are encountered, perform Resistance Resistance the preliminary checks below before referring to the...
  • Page 52: Troubleshooting

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Troubleshooting Outputs Fault Temp Conditions – This option displays the DXM2 The compressor and reversing valve relays are 24VAC temperature and voltage values when the lockout occurred.
  • Page 53: Dxm2 Process Flow Chart

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J DXM2 Process Flow Chart WARNING! WARNING! HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. Failure to disconnect power before servicing can cause severe personal injury or death.
  • Page 54: Functional & Performance Troubleshooting

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Functional Troubleshooting Fault Htg Clg Possible Cause Solution Check Line Voltage circuit breaker and disconnect Check for line voltage between L1 and L2 on the contactor Main Power Problems Green status LED off Check for 24VAC between R and C on DXM...
  • Page 55: Performance Troubleshooting

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Functional Troubleshooting (cont.) Fault Htg C lg Possible Cause Solution Heating Mode LT2>125°F Check for poor air flow or overcharged unit Unit Performance Sentinel-Code 8 Cooling Mode LT1>125°F OR...
  • Page 56 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Performance Troubleshooting Symptom Symptom Htg Clg Possible Cause Htg Clg Possible Cause Solution Solution Dirty filter Replace or clean Check for dirty air filter and clean or replace Rduced or no air flow...
  • Page 57 Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Performance Troubleshooting (cont.) Symptom Symptom Htg Clg Possible Cause Htg Clg Possible Cause Solution Solution Low Dischage Air Low Dischage Air Too high of air flow Check fan motor speed selection and airflow chart...
  • Page 58: Troubleshooting Form

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Troubleshooting Form Packaged Water-to-Air RP929 Troubleshooting Form Customer: Loop Type: Startup Date: Model #: Serial #: Antifreeze Type &...
  • Page 59: Warranty

    Tranquility ® 30 Digital (TE) Series IOM - 60Hz HFC-410A R e v. : 2 9 M a y, 2 0 1 5 J Warranty c l i m a t e m a s t e r. c o m...
  • Page 60: Revision History

    97B0045N04 ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi...