WARNING
Please read these instructions before installing or using this appliance for the first time. The
warranty of the storage heater will not cover any damage caused by non observance of any of
these instructions.
This Guide must be kept and given to any new owner.
The installation of the heater should be carried out by trained personnel.
The use of storage heaters is forbidden in any area where there is a presence of gases,
explosives or inflammable objects.
Do not dry clothes on or over heater.
Do not place objects in contact with the heater.
Do not cover this heater at any time.
The air outlet grille at the bottom of the heater cabinet and the air inlet at the right side of the
heater are provided to ensure the most efficient operation of the appliance. They also protect the
heater from overheating; therefore, it is essential that at no time they are covered.
This heater should be switched OFF at the isolating switch before any repair work is carried out.
Switch off during the times of year when heat is not required.
The installation of the heaters must be carried out in such a way that each pole can be
disconnected from the supply having a contact separation of at least 3 mm.
The storage heater should not be installed just bellow an electrical socket.
The appliance must be installed in such a way that it is impossible for anyone using a bath or
shower to touch the controls.
The nominal charging time of this storage heater must be controlled by means of a programmer.
The installation must be carried out in accordance with the current electrical regulations.
This appliance must be earthed.
Storage fan heaters need an ambient thermostat to operate (not included).
After installation, a survey of the first charging cycle should be carried out to ensure that the main
input thermostat switches OFF. Ventilate the room during this first cycle.
Never open a charged heater.
The presence in the air of particles of smoke, dust and other pollutants could, in time, discolour
the walls and surfaces around the heater. To maintain stability, it is essential that the heater is
placed on a level surface and care should be taken to avoid irregular surfaces, such as may result
from carpets or tiled surrounds partially protruding under the heater.
Should the heater be moved and reinstalled, it is essential that the work is carried out by trained
personnel.
If during any reinstallation the thermal insulation shows any sign of damage, it is necessary for the
faulty part to be removed and replaced by the identical part.