Kenmore 29" Installation Instructions Manual page 9

Wide gas (u.s.a. and canada) & electric (canada only) dryer

Advertisement

Available languages

Available languages

Option 2(Alternate
Method)
Approved
aluminum
orcopper tubing:
[] Lengths
under 20ft.(6.1 m ) c an use 3/8"approved
tubing
(ifcodes and gas supplier permit).
[] ifyou areusing Natural Gas, donot u se c opper tubing.
[] 3/8"flare x3/8"NPT a dapter fitting between
dryer pipe and 3/8"
approved
tubing.
[] Lengths
over 20ft.(6.1 m )should use larger tubing a nd adifferent
size a dapter fitting.
[] ifyour dryer has b een c onverted
touse LP gas, 3/8"LP compatible
copper tubing c an beused. Ifthe total l ength ofthe supply line is
more t han 20ft.(6.1 m ), u se l arger pipe.
NOTE: Pipe j oint c ompounds
that r esist the action ofLP gas must be
used. Do not u se TEFLON
®t t ape.
Dryer
gas
pipe
[]
The gas pipe
that comes
out through
the rear
of your
dryer
has a
3/8"
male
pipe
thread.
VENTING
Venting
Requirements
Fire Hazard
Use a heavy rnetal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
1¼"
(32 ram)
WARNING;
Toreducethe riskoffire, thisdryer MUSTBEEXHAUSTED
OUTDOORS.
IMPORTANT:
Observe
all governing
codes
and ordinances.
//
A
-=_-- 9¼"--_
(235 ram)
A. 3/8"
NPT dryer pipe
Burner input requirements
Elevations
up to lO,O00
ft. (3,048
an):
[]
The design
of this dryer
is certified
by CSA international
for use at
altitudes
up to 10,000
ft. (3,048
m), above
sea level at the B.T.U.
rating
indicated
on the model/serial
number
plate.
Burner
input
adjustments
are not required
when
the dryer
is operated
up to this
elevation.
Elevations
above
10,000
ft. (3,048
an):
[]
When
installed
above
10,000
ft. (3,048
m) a 4%
reduction
of the
burner
B.T.U. rating
shown
on the model/serial
number
plate
is
required
for each
1,000
ft. (305
m) increase
in elevation.
Gas supply
pressure
testing
[]
The dryer
must be disconnected
from
the gas
supply
piping
system
during
pressure
testing
at pressures
greater
than
1/2 psi.
Dryer
exhaust
must not be connected
into
any gas vent, chimney,
wall,
ceiling_
attic,
crawlspace,
or a concealed
space
of a building.
Only
rigid
or flexible
metal
vent shall
be used for exhausting.
((),
(102 mm)
t
4" (102 ram) heavy metal exhaust vent
[]
Only
a 4" (102 mm) heavy
metal
exhaust
vent and clamps
may
be
used.
[]
Do not use plastic
or metal
foil
vent.
Rig(c{
metal
vent:
[]
Recommended
for best drying
performance
and to avoid
crushing
and kinking.
F(ex(b(e
mete(
vent:
(Acceptable
only if accessible
to clean)
[]
Must
be fully
extended
and supported
in final
dryer
location.
[]
Remove
excess
to avoid
sagging
and kinking
that
may
result
in
reduced
airflow
and
poor
performance.
[]
Do not install
in enclosed
walls,
ceilings,
or floors.
[]
The total
length
should
not exceed
73¼ ft. (2.4 m).
NOTE:
If using an existing
vent system,
clean
tint from
entire
length
of
the system
and make
sure exhaust
hood
is not plugged
with
lint. Replace
plastic
or metal
foil
vents with
rigid
metal
or flexible
metal
vents.
Review
Vent
System
Chart
and if necessary,
modify
existing
vent
system to
achieve
best drying
performance.
t®TEFLON
is a registered
trademark
of E.I. Du Pont De Nemours and Company.

Advertisement

loading

This manual is also suitable for: