Kenmore 29" Installation Instructions Manual page 11

Wide gas (u.s.a. and canada) & electric (canada only) dryer

Advertisement

Available languages

Available languages

Alternate
installations
for dose
clearances
Venting
systems
come
in many
varieties.
Select
the type
best for your
installation.
Two close-clearance
installations
are shown.
Refer
to the
manufacturer's
instructions.
Over-The-Top
installation
(also
available
with
one offset
elbow)
Periscope installation
NOTE:
The following
kits for close clearance
alternate
installations
are
available
for purchase.
Ven_ing Ki_s
For more
information,
call ]=800=469=4663,
or visit us
at www.seors.com,
in Canada,
call
1-800-469-4663
or visit us at www.seors.co.
Port Number
Descrlpffons
8171587RP
0-5"
Metal
vent periscope
4396037RP
0"-18"
Metal
vent periscope
4396011RP
18" - 29" Metal
vent periscope
4396014
29" - 50" Metal
vent periscope
4392892
In-Wall
metal
DuraVent
TM
Periscope
4396028
Sure Connect
TM
venting
kit
(over-the-top
installation)
4396009RP
5' Universal
connect
vent, flexible
dryer
venting
4396010RP
6' SecureConnect
TM
vent, flexible
dryer
venting
4396013RB
Dryer
vent installer's
kit
4396033RP
5' flexible
dryer
venting
with
clamps
4396727RP
8' flexible
dryer
venting
with
clamps
4396004
Dryer
offset
elbow
4396005
Wall
offset elbow
4396006RW
DuraSafe
TM
close
elbow
4396007RW
Through-the-wall
vent cap
4396008RP
4" steel
dryer
venting
clamps
- 2 pack
8212662
Flush mounting
Iouvered
vent
hood 4"
Special
provisions
for
mobffe
home
instaffations:
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home.
Terminate
the exhaust
vent outside.
Determine
vent
path:
[]
Select
route that
will provide
straightest
and most direct
path
outdoors.
[]
Plan installation
to use fewest
number
of elbows
and turns.
[]
When
using elbows
or making
turns, allow
as much
room
as possible.
[]
Bend vent gradually
to avoid
kinking.
[]
Use as few
90 ° turns as possible.
Determine vent length and elbows needed for best drying
performance:
[]
Use following
Vent System
Chart
to determine
type
of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer
than
those specified
in Vent
System
Chart.
Exhaust
systems
longer
than
those
specified
will:
[]
Shorten
life of dryer.
[]
Reduce
performance,
resulting
in longer
drying
times
and increased
energy
usage.
The Vent System
Chart
provides
venting
requirements
that will help
achieve
best drying
performance.
(f
Vent
$, 'stem
Chart
Number of
90 ° turns or
elbows
0
1
4
Type
of vent
Rigldmetol
Rigldmetol
Rigldmetol
Rigldmetol
Rigldmetol
Box/Iouvered
Angled
hoods
hoods
64 ft. (20 m)
58 ft. (17.7 m)
54 ft. (16.5 m)
48 ft. (14.6
m)
44
ft. (13.4
m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4
m)
NOTE:
Side and bottom
exhaust
installations
have a 90 ° turn
inside
the dryer.
To determine
maximum
exhaust
length,
add
one 90 ° turn
to the chart.
11