Download Print this page

Kenmore 29" Installation Instructions Manual page 8

Wide gas (u.s.a. and canada) & electric (canada only) dryer

Advertisement

Available languages

Available languages

GROUNDING
iNSTRUCTiONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction
or
breakdown,
grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor
and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance
with all local codes
and ordinances.
WARNING-"
Improper connection of the equipment-
grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion Hazard
Use a new CSA International approved
gas supply line.
instal[ a shut=off valve.
Securely tighten
all gas connections.
If connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified
person include:
licensed
heating
personnel,
authorized gas company personnel, and
authorized
service personnel.
Failure to do so can result
in death, explosion,
or fire.
Gas
type
Natural
gas:
This dryer
is equipped
for use with
Natural
Gas.
It is design-certified
by
CSA International
for LP (propane
or butane)
gases with
appropriate
conversion.
[]
Your dryer
must have the correct
burner
for the type
of gas
in your
home.
Burner information
is located
on the rating
plate
in the door well
of your
dryer.
If this information
does
not agree
with
the type
of gas available,
please
reference
the
"Assistance
or Service"
section
of the "Use and
Care Guide".
LP gas conversion:
Conversion
must
be made
by a qualified
technician.
No attempt
shall
be made
to convert
the dryer
from
the gas specified
on the model/serial
rating
plate
for use with
a different
gas without
consulting
the serving
gas supplier.
IMPORTANT:
The gas installation
must conform
with
local
codes,
or in the
absence
of local
codes,
with
the National
Fuel Gas Code,
ANSi
Z223.1/
NFPA 54 or the Canadian
Natural
Gas and Propane
Installation
Code,
CSA B149.1.
Gas supply line
[]
[]
[]
[]
1/2"
NPT pipe
is recommended.
3/8"
approved
tubing
is acceptable
for lengths
under
20 ft. (6.1 m) if
local
codes
and gas supplier
permit.
Must include
1/8"
NPT minimum
plugged
tapping
accessible
for test
gauge
connection,
immediately
upstream
of the gas connection
to
the dryer
(see illustration).
Must include
a shutoff
valve:
in the U.S.A.:
An individual
manual
shutoff
valve
must be installed
within
six (6) feet
(1.8 m) of the dryer
in accordance
with
the National
Fuel
Gas Code,
ANSI
Z223.1.
in Canada:
An individual
manual
shutoff
valve
must be installed
in accordance
with
the B149.1, Natural
Gas and
Propane
Installation
Code.
It is
recommended
that an individual
manual
shutoff
valve
be installed
within
six (6) feet (1.8 m)
of the dryer.
The shut off valve location should be easy to reach for opening and
closing.
E
B
A. 3/8"
flexible
gas connector
B. 3/8"
pipe to flare adapter
fitting
C. 1/8" NPT minimum plugged
tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
Gas
supply
connection
requirements
There are
many
methods
by which
your
gas dryer
can be connected
to
the gas supply.
Listed here are some guidelines
for two different
methods
of connection.
Option I (Recommended
Method)
Flexible stainless steel gas connector:
[]
If local
codes
permit,
use a new flexible
stainless
steel gas connector
(Design
Certified
by the American
Gas Association
or CSA
International)
to connect
your
dryer
to the rigid
gas
supply
line. Use
an elbow
and a 3/8"
flare
x 3/8"
NPT adapter
fitting
between
the
stainless
steel gas connector
and the dryer
gas
pipe, as needed
to
prevent
kinking.

Advertisement

loading

This manual is also suitable for:

110719231211071402312110c61402311