Table 13. The Homologation Parameters (continued)
Par #
Parameter Description
31
TAD receive gain
32
Half/full wave ring detection
33
Number of failed attempts allowed in first stage
delayed dialing
34
Number of all failed attempts ( to any number)
allowed before any further dial attempts are blocked
35
Erroneous call increment count
36
Dial tone validation time in multiples of 100 ms
37
Busy tone detection during dial tone detection flag
38
DTMF high and low tone level difference in dB
39
Local phone detection in speakerphone
3a
Pulse dialing flag
3b
Dial tone/call progress filter index
3c
Dial tone detection threshold in dB
3d
ABCD dialing permitted flag
3e
Comma pause duration limit in seconds. (If there are
multiple commas between digits, the total pause
duration is limited to the duration set by this
parameter).
3f
TAD transmit level in dB
40
Data/FAX carrier receive threshold in dB. There is a 6
dB offset in DSP. This parameter value should set to:
(required threshold [6 dB] DAA gain)
41
No dialtone time-out duration while detecting dialtone
with W dial modifier, in seconds
42
FAX/Data answer tone detection threshold in dB
43
Dialtone level (absolute value)
44
FAX receive threshold in dB
45
Pulse and tone dial in same dial string permitted flag
46
Ringer impedance relay flag
47
DC loop V/I characteristics relay flag
48
DC loop limiting relay flag
49
Real/complex impedance
4a
Mercury register CIOCA MSB value—receive gain
Version 1.0
0—255
0 = halfwave, 1 = fullwave
0—255
0—255
255 = not applicable
0—255
0—255
0 = not required, 1 = required
0—255
0 = enabled; 1 = disabled
0 = enabled; 1 = disabled
0 = 340—560 Hz
2 = 363—502 Hz
4 = 415—460 Hz
0—255
0 = permitted, 1 = not permitted
0—255
0—255
0—255
0—255
0—255
0—255
0—255
0 = permitted, 1 = not permitted
0 = off, 1 = on
0 = off, 1 = on
0 = off, 1 = on
0x0X = real, Tx & Rx gains set by mercury
internal components. X = Don't care
0x10 = real, Tx gain set by mercury
internal components & Rx gain set by
external components.
0x12 = complex, Tx gain set by mercury
internal components & Rx gain set by
external components. Mercury internal
switch used to select complex impedance.
This parameter is relevant only when a Mercury
line codec is used.
Lucent Technologies Inc.
Host-Based Controller Modem

AT Command Set

Range
1 = 310—485 Hz
3 = 276—504 Hz
5 = 310—640 Hz
Reference