Fujitsu MAA3182SC Oem Manual page 25

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

(1)
GOOD Status
This status indicates that execution of the command ended normally.
(2)
CHECK CONDITION Status
This status is reported in the following cases a) to c). The IDD generates sense data when it
reports this status and displays the detailed cause. The INIT issues a REQUEST SENSE
command when it receives this status and should sample sense data.
a) If the sense key of the sense data indicates RECOVERED ERROR [=1], the last command,
which is the final command, indicates that it ended normally with the error recovery
processing executed by the IDD.
b) If the sense key of the sense data indicates UNIT ATTENTION [=6], it indicates that the
IDD was holding the UNIT ATTENTION condition. Details of the UNIT ATTENTION
condition are described in section 1.5.
c) In cases other than the above, it indicates that command execution is impossible, or that
command execution was terminated abnormally.
(3)
CONDITION MET Status
This status indicates that the PRE-FETCH command condition has been met, and is reported
when it is possible to secure the cache memory area necessary for reading all the logical data
blocks specified in the PRE-FETCH command (in the case of "Immed = 1"), or when reading
of all the specified logical data blocks is completed (in the case of "Immed = 0").
The IDD does not support the PRE-FETCH command. Therefore, reporting of this status is
not reported.
(4)
BUSY Status
This status indicates that the IDD is in the busy state or that it cannot receive a new command.
Normally, an INIT that receives this status reissues the original command after waiting an
appropriate period of time.
The IDD reports the BUSY status in the following cases (the command stack function is
explained in section 1.4).
a) If the IDD receives a new command while it is executing a command, is queuing or is
executing its initial self-diagnosis (except a command with an object other than disconnect
processing as shown in item 1.3.3), if the INIT which issued that command does not
satisfy the disconnect enable conditions.
b) If the IDD receives a command with an object other than disconnect processing (as shown
in item 1.3.3) while it is executing a command, is queuing or is executing its initial self-
diagnosis.
c) If the DISCONNECT message for command queuing has been rejected by the INIT.
d) If a command with untagged disconnect processing as its object is received while the
command queue is full.
1 - 8
C141-E039-01EN