Fujitsu MAA3182SC Oem Manual page 215

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

C*
Q*
Name
C4
11 Drive failure
E0
nn Microprogram detected A logical contradiction or similar error in the IDD's
* C: Sense Code, Q: Sub-sense Code
4 - 12
Table 4.2
Sense and subsense codes (7 of 7)
A serious error was detected in the drive's control
system. ('nn' is a Fujitsu unique code (00 to FF)
microcode was detected.
('nn' is a Fujitsu unique code (80 to FF).)
• 80: An undefined Unit Check condition was
detected.
• 81: A3 abnormal during sense creation.
• 90: An unexpected sequence step was detected in
the bus sequence.
• 91: An error occurred on the SCSI bus.
• A0: A Native internal command was issued in
duplicate.
• A1: ECC logging overflow
• A2: A contradiction occurred in the Sequence table
value during Read retry.
• A4: The target position of an internal seek command
was illegal.
• A5: The Format command was issued in duplicate.
• A6: The transfer byte count specified in DE
contradicts the FMT recognition.
• A7: The USP stack pointer's value is abnormal.
• B0: A contradiction occurred in the defect
management table.
• C0: An odd number was specified in the address
specified for transfer.
C141-E039-01EN
Explanation
Sense
key
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mab3091sc