Fujitsu MAA3182SC Oem Manual page 222

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

Table 4.3
K*
C*
Q*
5
20
00 Invalid command operation code
21
00 Logical block address out of range
24
00 Invalid field in CDB
25
00 Logical unit not supported
26
00 Invalid field in parameter list
2C
00 Command sequence error
There is an error in the command specification
contents.
5
3D
00 Invalid bits in IDENTIFY message
90
00 Initiator's SCSI ID not identified
An error was detected in the SCSI protocol in
the command execution sequence.
6
29
xx Power on, reset, or BUS DEVICE RESET occurred
The IDD was initialized by a Power on,
RESET condition or BUS DEVICE RESET
6
2A
01 Mode parameters changed
The MODE SELECT parameters were
changed by another INIT.
5C
00 RPL status changed
The RPL parameters were changed by another
INIT..
6
2A
02 Log parameters changed
The LOG SELECT parameters were changed
by another INIT.
6
2F
00 Commands cleared by another INIT
Commands were cleared by another INIT.
6
3F
00 Target operating conditions have been changed
The operation code was changed by another
INIT.
6
5B
01 Log exception (Threshold condition met)
The current cumulative value exceeded the
current threshold value.
02 Log count at maximum
The current cumulative value reached the
maximum value.
6
5C
01 Spindle synchronized
Rotational synchronization was completed.
*
K: Sense Key
Q: Sub-sense code
Sense data error classification (3 of 4)
Outline of Error
message.
C: Sense Code
L: Logging Necessary? (shown in item 4.2.3)
C141-E039-01EN
Recovery Method
L*
(See Table 4.4.)
None
2
None
3
None
14
None
21
None
16
None
25
None
27
None
26
None
22
4 - 19