DOCUMENT PURPOSE This document describes how to configure GXP1610/ GXP 1620/GXP1625 feat ures via phone’s LCD menu and Web GUI menu. The intended audienc es of this document are phone administrators . To learn the basic functions of GXP1610/GXP 1620/GXP1625, pleas e visit http://www.grandstream.com/support...
GNU General Public License (GPL) for the exact terms and conditions of the license. Grandstream GNU GPL related source code can be downloaded from Grandstream web site from: http://www.grandstream.com/support/faq/gnu_gpl. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 7 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
GXP1610/GXP1620/GXP 1625. Only major new features or major document updates are listed here. FIRMWARE VERSION 1.0.0.35 This is the initial version. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 8 of 45 Administration Guide...
IP phone: the GXP1620/ GXP 1625 features 2 lines with 2 SIP accounts, superior HD wideband audio, 132 x 48 backlit graphical LCD; the GXP1610 supports 2 lines with 1 SIP account, 132 x 48 graphical LCD. The GXP1610/GXP1620/GXP 1625 delivers rich features of...
Page 11
Reproduction or transmittal of the entire or any part, in any form or by any means, electronic or print, for any purpose without the express written permission of Grandstream Networks, Inc is not permitted. FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
CONFIGURATION GUIDE The GXP1610/GXP1620/GXP1625 can be configured via two ways: LCD Configuration Menu using the phone's keypad; Web GUI embedded on the phone using PC's web browser. CONFIGURATION VIA KEYPAD To configure the LCD menu using phone's keypad, follow the instructions below: ...
Adjusts ring volume by pressing left/right arrow key. LCD Contrast Adjusts LCD contrast by pressing left/right arrow key. LCD Brightness (Not applicable to GXP1610) Preference Adjusts LCD brightness of idle state and active state by pressing left/right arrow key. ...
Specifies Protocol, IP and Port of the target UCM server Reboot Reboots the phone The following picture shows the keypad MENU configuration flow. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 16 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
CONFIGURATION VIA WEB BROWSER The GXP1610/GXP 1620/GXP1625 embedded Web server responds to HTTP/HTTPS GE T/POST requests. Embedded HTML pages allow a user to configure the IP phone through a Web browser such as Microsoft’s IE, Mozilla Firefox and Google Chrome.
DEFINITIONS This section describes the options in the GXP1610/GXP 1620/GXP1625 Web GUI. As mentioned, you can log in as an administrator or an end user. Status: Displays the Account status, Network status, and System Info of the phone. ...
Core dump file that could be downloaded for troubleshooting purpose. ACCOUNT PAGE DEFINATIONS The GXP1610/ GXP 1620/GXP1625 has two lines that can be configured to accommodate independent SIP accounts. Every SIP account has an individual configuration page. Account x -> General Settings Account Active This field indicates whether the account is active.
Configures to remove outbound proxy from route. This is used for the SIP route Extension to notify the SIP server that the device is behind a NAT/Firewall. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 21 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Session Expiration "refreshed" via a S IP request (UP DA TE, or re-INVITE ). If there is no refresh Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 22 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Enables the SRTP mode based on your selection. The default setting is SRTP Mode "Disabled". Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 23 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
2, replacing the 2 with 011 when dialed. Example of a simple dial plan used in a Home/Office in the US: Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 24 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Caller ID to be displayed. Anonymous Call If set to "Yes", anonymous calls will be rejected. The default setting is "No". Rejection Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 25 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Off-hook Auto Dial hook. The phone will use the first account to dial out. The default setting is "No". Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 26 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Message Waiting Syntax: f1=val,f2=val[,c=on1/off1[-on2/off2[-on3/off3]]]; Ring Back Tone (Frequencies are in Hz and cadence on and off are in 10ms) Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 27 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Configures the LCD backlight brightness level (from 0 to 8) for phone's active status. The default value is 6. Backlight Brightness: Active Note: This options is not applicable to GXP1610. Configures the LCD backlight brightness level (from 0 to 8) for phone's idle status. The default value is 2. Backlight Brightness: Idle...
This option is not applicable to GXP1610. Settings -> Date and Time Defines the URL or IP address of the NTP server. The phone may obtain the NTP Server date and time from the server. Defines whether DHCP Option 42 should override NTP server or not. When...
Allows users to configure the appropriate network settings on the phone to IPv4 Address Type obtain IP v4 address. Users could select "DHCP", "Static IP" or "PPPoE". By Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 30 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Configures the P C port mode. When set to "Mirrored", the traffic in the LAN PC Port Mode port will go through PC port as well and packets can be captured by Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 31 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
TFTP server. Lat er on it was extended to support an HTTP URL. GXP phones Server support both TFTP and HTTP server via option 66. Users can also use DHCP Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 32 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
The user name for the ACS to connect to the phone. Username Connection Request The password for the ACS to connect to the phone. Password Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 33 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Configures the phonebook download interval (in minutes). If it's set to 0, the Interval automatic download will be disabled. The default value is 0. The valid range is Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 34 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
LDAP search res ult. This field allows the users to configure multiple space LDAP Number Attributes separated number attributes. Example: telephoneNumber Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 35 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Select Keep-Alive, Auto, STUN (with S TUN server path configured too) or other option according to the network setting. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 36 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
PUBLIC MODE The GXP1610/GXP 1620/GXP1625 supports hot desking using public mode. Under public mode, users could login the phone wit h the S IP account User ID and password. Please follow the steps below to configure the phone for public mode: ...
The account index for the phone to make call. The index is 0 for account 1 and 1 for account 2. password=admin/123: The admin login password or user login password of phone's Web GUI. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 38 of 45 Administration Guide VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299...
Press the "Reboot" button on the top right corner of the web GUI page to reboot the phone remotely. The web browser will then display a reboot message. Wait for about 1 minute to log in again. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 40 of 45 Administration Guide...
When upgrading starts, the screen will show upgrading progress. When done y ou will see the phone restart again. Please do not interrupt or power cycle the phone when the upgrading process is on. Firmware Version 1.0.0.35 GXP1610/GXP1620/GXP1625 Page 41 of 45 Administration Guide...
LAN environment whenever possible. Note: Please do not interrupt or power cycle the GXP1610/GXP 1620/GXP1625 when the upgrading process is NO LOCAL TFTP/HTTP SERVERS For users that would like to use remot e upgrading without a local TFTP/HTTP server, Grandstream offers a NAT-friendly HTTP server.
Access page. For a detailed parameter list, please refer to t he corresponding firmware release configuration template. When GXP1610/GXP 1620/GXP1625 boots up, it will send TFTP or HTTP/ HTTPS requests to download configuration files, “cfg000b82xxxxxx” and“cfg000b82xxxxxx.xml”, where “000b82xxxxxx” is the MAC address of the phone.
Press the "OK" softkey to confirm and the phone will reboot. To c ancel the Reset, press "Cancel" softkey instead. RESTORE TO FACTORY DEFAULT VIA THE WEB GUI Login GXP1610/GXP1620/GXP1625 Web GUI; Direct At the top right corner of the web page, click “Factory Reset” button to reset the device. Firmware Version 1.0.0.35...
EXPERIENCING THE GXP1610/GXP1620/GXP1625 Please visit our website: http://www. grandstream.com to receive the most up- to-date updates on firmware releases, additional features, FAQs, documentation and news on new products. We encourage you to browse our product related documentation, FAQs User and Developer Forum for answers to your general questions.