A 115 volt, 60 Hz, 15 amp
fused electrical supply is
required. It is recommended
a separate circuit, serving
only this appliance, be
provided.
All Sub-Zero units are
equipped with a power supply
cord with a 3-prong grounding
plug and it must be plugged
into a mating 3-prong ground-
ing type wall receptacle.
Follow the National Electrical
Code and local codes and
ordinances when installing
the receptacle. Refer to
figures and chart on page 10
for exact specifications.
For units with an automatic
ice maker, rough in the water
supply line. Connect a VI" OD
copper line to the house
supply being sure to use an
easily accessible shut off
valve between the supply and
the refrigerator.
Do not use "self-piercing"
valves. A saddle valve kit
able from your distributor/
dealer. A line filter is required
when water conditions have
a high sediment content.
The water line should be
routed up through the floor
within %" from the back wall
no higher than 3" off the
floor. If you have to come
through the wall, make sure
the water line is no more than
3" from the floor.
Regardless of the routing,
allow two to three feet of
excess copper tubing to
remain outside the wall or
floor for easy connection to
the unit. Refer to figures and
chart on page 10 for exact
specifications.
It is important to keep in
mind that all installations
must allow for the units
to open a minimum of 90
degrees or you will have
problems removing crispers
and drawers. With the door
opening at 90 degrees, you
may have to move drawers
or crispers slightly to clear
the door interior. Refer to
minimum door clearance on
page 10.
For corner installations,
l
you must allow for a
minimum two inch filler to
assure door opens to 90
degrees. Where raised panels
to
are used, you may want
consider a wider filler.
Strip
Figure 3
When units are installed
l
side by side a filler strip is
recommended. Depending on
the configuration and panels
used, this filler strip will vary.
Keep in mind the filler strip
l
width should be added to
your finished rough in dimen-
sion. In any side by side
installation, an additional half
inch should be added to your
combined numbers.
pages ZOA
and IOB, Figures
and C for specifics on
A, B
door openings and filler size
Figure 4
(Optional D-Style
Handle shown)