KitchenAid YKDRP707 Installation Instructions Manual page 5

Dual fuel convection range with steam-assist
Hide thumbs Also See for YKDRP707:
Table of Contents

Advertisement

Available languages

Available languages

Grounded electrical supply is required. See "Electrical
Requirements" section.
Proper gas supply connection must be available. See "Gas
Supply Requirements" section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C). Use an
insulated pad or ¼" (0.64 cm) plywood over carpet and under
range if installing range over carpeting.
IMPORTANT: Some cabinet and building materials are not
designed to withstand the heat produced by the oven for baking
and self-cleaning. Check with your builder or cabinet supplier to
make sure that the materials used will not discolor, delaminate or
sustain other damage.
30" (76.2 cm) models
G
F
E*
A. Backguard (required for some installations)
B. 45" (114.3 cm) overall height
C. 36" (91.4 cm) cooktop height with feet loosened ¾ turn
D. 30" (76.2 cm) width
E. 26½" (67.3 cm) width with control panel, see NOTE*
F. ¼" (6.4 cm) spacer
G. 9¼" (23.5 cm) backguard height
*NOTE: When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop; front of oven door protrudes 1⁷⁄₈" (4.8 cm) beyond
24" (61 cm) base cabinet.
Product Dimensions
A
B
C
D
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
36" (91.7 cm) models]
G
F
E*
A. Backguard (required for some installations)
B. 45" (114.3 cm) overall height
C. 36" (91.4 cm) cooktop height with feet loosened ¾ turn
D. 36" (91.4 cm) width
E. 26½" (67.3 cm) width with control panel, see NOTE*
F. ¼" (6.4 cm) spacer
G. 9¼" (23.5 cm) backguard height
A
B
C
D
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ykdrp767

Table of Contents