Baxi Solo 3 PFL 30 User Operating Instructions Manual page 6

Wall mounted powered flue gas fired central heating units solo 3 pfl range
Table of Contents

Advertisement

5mm
350mm (30,40,50 models)
462mm (60,70,80 models)
50mm
600mm
100mm
Fig. 7
6
© Baxi Heating UK Ltd 2009
5mm during operation
5mm
300mm for servicing
4.0 Clearances
4.1
Clearances around the boiler (Fig. 7)
1. The minimum clear spaces needed around the boiler
are:
Top:
Bottom:
Sides:
Front:
2. These clearances must not be obstructed in any
way. Blocking the clearance spaces will result in the
appliance overheating and possible damage may occur.
3. The boiler may be installed in a cupboard if these
minimum clearances are kept. Note that the label affixed
to the front of the boiler must be left in place to ensure
future servicing is successfully undertaken.
287mm
4. The compartment should be large enough to house
the boiler and ancillary equipment only.
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
6. The gas burning compartment of your boiler is
completely sealed from the room in which it is fitted.
Products from the combustion of gas are vented to the
outside through the flue terminal which must be kept
free from obstruction as this would interfere with the
correct operation of the boiler.
50mm (2 in)
100mm (4 in)
5mm (
3
/
in)
16
5mm (
3/
in)
16