BRAND NAME
CUBE
ITEM
Water
Cold Water Temperature
Hot Water Temperature
Recommended Service Pressure 40-60 psi (275-414 kPa) – Use Pressure Regulator
Maximum Working Pressure
Environmental Temperature
Refrigerant Gas
R134a Pressures
ITEM
#
Width/Depth/Height
Weight – Dry (w/o packaging)
Shipping Information
(length x width x height)
Shipping Weight – Dry
ELECTRICAL SUPPLY
COMPONENT
Heater
Compressor
UV Lamp System
Pump
CUBE TOTAL
#CUBE is 17 in. tall and may not fit between countertops and cabinets - Check installation to ensure adequate clearance.
CUBE Operating, Installation, and Service Manual
MODEL/PART DESIGNATIONS
DESCRIPTION
Waterlogic CUBE – Ambient, Cold, Hot, and Extra Hot
F-FWCU1-M-HCA-TT-SB-IN1

SPECIFICATIONS

¼" Quick Connect
Cold Water Temperature – Factory Set Point 41°F - 5°C
(Adjustable) 34° - 54° F. (1.1° - 12.2°C)
158° - 203° F (70° - 95°C) Programmable – Factory Set Point 87°F – 30.5C°
60 psi (414 kPa) – Use Pressure Regulator
35° - 100°F (2° - 37°C)
R134a – 1.94 oz. (55 grams) - Hi (280 psi) Low (90 psi)
High (230 psi), Low (90 psi)
SHIPPING SPECIFICATIONS
14 in (356 mm), 19 in (483 mm) x 17 (432,m).
30 lb. (15 kg)
20 in. x 22 in. x 22 in.
8 units per pallet
41 lb. (19 kg)
ELECTRICAL SPECIFICATIONS
120V/60Hz
POWER (approximate)
500 Watts
210 Watts
13 Watts
10 Watts
733 Watts
#
+
15 Amp Service
AMP DRAW (approximate)
4.2 Amps
1.75 Amps
0.11 Amps
0.08 Amps
6.14 Amps