Sanitizing
WARNING!
Read and understand the contents of this manual before attempting to service
CUBE. Failure to follow the instructions in this manual could result in death, serious personal
injury, or severe property damage. Only trained and qualified technicians should attempt to
install, maintain, or service Waterlogic Equipment.
Materials Needed:
• Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
• Phillips Screwdriver.
• Replacement filter cartridge(s)
• New 13 Watt UV lamp
• Water Pitcher or Container to collect water from the faucet
• 5 gallon container or drain basin
• Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
1.
Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
2.
Waterlogic recommends changing the UV Lamp every 12 months.
WARNING!
rays. Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
must be disposed of accordingly. Refer to Product MSDS sheet for details.
3.
Turn off the incoming water supply at the isolation point
4.
Select the Cold Water icon and then select the dispense button.
When the water stops flowing release the button
5.
Switch Off the Red Power Switch and the Green
Heater/Compressor switches at the rear of the machine
and remove the power lead from the Cube. O=OFF
CUBE Operating, Installation, and Service Manual
HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
ULTRAVIOLET RADIATION. Protect your skin and eyes against ultraviolet
UV LAMPS ARE HAZARDOUS. Lamps are considered Hazardous Waste and