HAKO Scrubmaster E10 Instruction Manual page 23

Table of Contents

Advertisement

Technical Data
Elektric system
Service voltage
Mains frequency
Protection class, compl. machine
Protection type, compl. machine
Nominal rating, total, max.
Fuse for brush motor
Fuse for suction motor
Fuse for pump
Brush motor
Suction turbine
Pump
Noise emission value
The sound pressure level (LpA) (at the ear of the operator) measured
according to DIN IEC 60335-2-72 under normal working conditions:
Measurement inaccuracy (KpA):
Vibration
The weighted effective value of acceleration, measured in accordance
with ISO 5349-1, to which the upper parts of the body (hand-arm) are
exposed under normal working conditions:
The weighted effective value of acceleration, measured in accordance
with ISO 2631-1, to which the upper parts of the body (feet-seat) are
exposed under normal working conditions:
AC/Volt
HZ
EN 60335-2-72
EN 60335-2-72
W
A
A
A
W
W
W
dB (A)
dB (A)
m/s²
m/s²
230 ± 10%
50
I
IP X3
1340
5
T 6.3
T 0.5
600
850
16
72
2
< 2,5
< 0,5
23

Hide quick links: