No.
Page
Item
P04
GAMMA
GAMMA
STEP GAMMA
MASTER GAMMA
R GAMMA
G GAMMA
B GAMMA
TEST OUT SELECT
GAMMA SELECT
GAM SEL (STD)
GAM SEL (FILM)
P05
BLACK GAMMA BLACK GAMMA
BLACK GAM RANGE
MASTER BLK
GAMMA
R BLACK GAMMA
G BLACK GAMMA
B BLACK GAMMA
TEST OUT SELECT
P06
KNEE
KNEE
KNEE POINT
KNEE SLOPE
KNEE SATURATION
KNEE SAT LEVEL
WHITE CLIP
WHITE CLIP LEVEL
P07
DETAIL 1
DETAIL
APERTURE
DETAIL LEVEL
APERTURE LVL
DTL H/V RATIO
CRISPENING
LEVEL DEPEND
LEVEL DEPEND LVL
DETAIL FREQUENCY (–99 to +99)
Settings
Default Description
OFF/ON
ON
Turns the gamma correction function on/off.
0.35 to 0.90
0.45
Sets the master gamma correction curve in
steps.
(–99 to +99)
0
Sets the master gamma correction curve.
(–99 to +99)
0
Sets the R gamma correction curve.
(–99 to +99)
0
Sets the G gamma correction curve.
(–99 to +99)
0
Sets the B gamma correction curve.
ENC/R/G/B
ENC
Selects the output signal of TEST OUT
connector.
STD/FILM
STD
Selects the gamma table.
1 to 6
3
Selects the gamma table of STD.
1 to 5
1
Selects the gamma table of FILM.
OFF/ON
OFF
Turns the black gamma correction on/off.
LOW/L.MID/
HIGH
Sets the range affected by black gamma.
H.MID/HIGH
(–99 to +99)
0
Adjusts the master black gamma.
(–99 to +99)
0
Sets the correction curve of the R black
gamma.
(–99 to +99)
0
Sets the correction curve of the G black
gamma.
(–99 to +99)
0
Sets the correction curve of the B black
gamma.
ENC/R/G/B
ENC
Selects the output signal of TEST OUT
connector.
OFF/ON
ON
Turns the knee correction circuit on/off.
50 to 109%
85.0
Sets the knee point level.
(–99 to +99)
0
Set the knee slope level.
OFF/ON
ON
Turns the knee saturation function on/off.
(–99 to +99)
0
Sets the knee saturation level.
OFF/ON
ON
Turns the white clipping function on/off.
100.0 to 109.5% 109.0
Adjusts the white clipping level.
(MSW-
970)/
105.0
(MSW-
970P)
OFF/ON
ON
Sets the detail correction function on/off.
OFF/ON
ON
Turns the aperture correction function on/off.
(–99 to +99)
0
Sets the general level of the detail signal.
(–99 to +99)
0
Sets the aperture level.
(–99 to +99)
0
Sets the level of the V detail signal.
(–99 to +99)
0
Sets the crispening level.
OFF/ON
ON
Turns the level depend function on/off.
(–99 to +99)
0
Sets the level of the level depend.
0
Sets the frequency of the H detail signal.