WARNING: Maintain the
minimum
clearances
i n
F i g u r e 4 .
I f
provide greater clearances from
floor, ceiling, and joining wall.
Figure 4 -Mounting Clearances
As Viewed From Front Of Heater
IMPORTANT:
heaters add moisture to
air. Although this is beneficial,
ins tall ing
heater
without enough ventilation air
may
cause mildew to
from too much moisture. See
Fresh Air for Combustion and
Ventilation, pages 4 and 5.
INSTALLING THERMOSTAT
SENSING BULB
For T-Stat Models Only
1. Pull out the sensing bulb from the
two clips located in the shippng
position according to the direction
as shown by the arrow. There is no
need to take out the two bulb clips.
2. Take out the bulb clip from the
hardware package and insert it into
the square hole and then insert the
sensing bulb into the bulb clip (see
Figure 5).
Figure 5 - Moving Thermostat
Sensing Bulb
INSTALLATION
FASTENING HEATER TO
WALL Mounting Bracket
shown
The mounting bracket is located
y o u c a n ,
on back panel of heater (see Figure6).
It has been taped there for shipping.
Remove mounting bracket from back
panel.
Figure 6 -Mounting Bracket
Removing Lower Front Panel Of
The Heater
1. Remove two Screws near bottom
corners of lower front panel
2. Pull bottom of lower front panel
forward, then down (see Figure 7).
Vent-free
the
in
rooms
form
Figure 7 - Removing Lower Front
Panel Of Heater
Methods For Attaching
Mounting Bracket To Wall
Only use last hole on each end
of mounting bracket to attach
bracket to wall. These two holes
are 16 inches apart from their
c e n t e r s .
bracket to wall only in one of two
ways:
1.
Attaching to wall stud
2.
Attaching to wall anchor
Attaching to Wall Stud: This
method provides the strongest
hold.
Insert
through mounting bracket and
into wall studs.
Location
A t t a c h
m o u n t i n g
mounting
screws
7
Attaching to Wall Anchor: This
m ethod
allows
you
mounting bracket to hollow walls
(wall areas between studs) or to
solid walls (concrete or masonry).
Decide which method better
your needs. Either method
provide a secure
hold for the
mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall
where heater will be located.
Make sure mounting bracket is
level.
WARNING:
minimum clearances shown in
Figure 8. If you can, provide
greater clearances from floor
and joining wall.
2.
Mark
screw
locations
wall. (see Figure 8)
Note: Only mark last hole on
each end of mounting bracket.
Insert mounting screws through
these holes only.
3.
Remove tape and mounting
bracket from wall.
Model MN300HPA MN300TPA
Model MN180HPA MN180TPA
Figure 8 - Mounting Bracket
Clearances
to attach
suits
will
Maintain
on
Need help?
Do you have a question about the MN180HPA and is the answer not in the manual?
Questions and answers