6.4.3 Fiber Optic Ethernet Port Specifications
Speed
Order
Mode
Standa
Code
Connector
rd
MJ
100FX
MM/MTRJ
MC
100FX
MM/SC
MT
100FX
MM/ST
ML
100FX
MM/LC
T2
100FX
SM/ST
L2
100FX
SM/LC
C2
100FX
SM/SC
L5
100FX
SM/LC
C5
100FX
SM/SC
L9
100FX
SM/LC
C9
100FX
SM/SC
Table 17 - Fiber Optic Port Specifications
NOTES:
1. All values listed are average values
2. To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3
dBm.
3. Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2010 RuggedCom Inc.
Cable
Tx
/
Tx
Type
min
(nm)
(um)
(dBm)
1300
50/125
-22.5
62.5/125 -19
1300
50/125
-22.5
62.5/125 -19
1300
50/125
-22.5
62.5/125 -19
1310
62.5/125 -19
1310
9/125
-15
1300
9/125
-15
1300
9/125
-15
1310
9/125
-5
1310
9/125
-5
1310
9/125
0
1310
9/125
5
36
Tx
Rx
Rx
max
Sensitivity
Saturation
(dBm)
(dBm)
(dBm)
-14
-33.5
-14
-14
-33.5
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-33.9
-14
-14
-32
-14
-7
-34
-3
-8
-38
-3
-8
-31
-7
0
-35
-3
0
-34
-3
5
-37
0
0
-37
0
Typical
Power
Distance
Budget
(km)
(dB)
2
11
2
14.5
2
11.4
2
14.9
2
11.4
2
14.9
2
13
20
19
20
23
20
16
50
30
50
29
90
37
90
42
Rev107