4.6 Fiber Optic Ethernet Port Specifications
Speed
Mode /
Standard
Connector
100Base-FX
MM / ST
100Base-FX
MM / SC
100Base-FX
MM / LC
100Base-FX
MM / MTRJ
100Base-FX
SM / ST
100Base-FX
SM / SC
100Base-FX
SM / LC
Table 13 - Fiber Optic Port Specifications
NOTES:
1.
Maximum segment length is dependent on factors such as fiber quality, and number of patches and splices.
Please consult RuggedCom sales associates when determining maximum segment distances.
2.
To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
4.7 Communication Standards
Protocol
Ethernet
VDSL
Table 14 - Communication Standard Compliance
©
2007 RuggedCom Inc. All rights reserved
All manuals and user guides at all-guides.com
Cable
Tx Pwr
λ λ λ λ
Tx
Type
2
(dBm peak)
(nm)
µ µ µ µ m)
(Min / Max)
(
1310
50/125
-15.7
1310
50/125
-16/-11
1310
50/125
-19 / -14
1310
50/125
-16/-11
1310
9/125
-15/-8
1310
9/125
-13/5
1310
9/125
-15/-8
ETSI TS 101 270-2 V1.1.1, ITU-T G.993.1, ANSI T1E1.4
22
Rx
Rx Saturation
3
Sensitivity
(dBm Peak)
(dBm Average)
3
-33.5
-33
-32
-33.5
-32
-31
-31
Standards
IEEE 802.3
Typical
Power
Distance
Budget
3
(km)
1
(dB)
-11
2
17
-11
2
17
-14
2
15
-11
2
17
-7
20
16.5
-4
20
20
-5
15
16.5
Rev101
Need help?
Do you have a question about the RuggedSwitch RS900L and is the answer not in the manual?