7.
With Control Knob pressed in, push and release the ignitor button. This will light the pilot. If needed, keep
pressing ignitor button until pilot lights.
8.
Keep Control Knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 6, 7 and 8.
9.
Turn counterclockwise
TO TURN OFF GAS TO APPLIANCE
Push in gas Control Knob slightly and turn clockwise
When electric power is available and electric operation is desired, turn clockwise
minute. Then press down knob and rotate clockwise
Do not operate between locked positions.
MANUAL LIGHTING PROCEDURE
(match light)
1.
Open front door.
2.
Follow steps 1 through 5 under MANUAL OPERATING Lighting Instructions.
3.
With Control Knob in PILOT/IGN position, strike match, and hold near pilot. Press in Control Knob, pilot
should light.
4.
Keep Control Knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release Control Knob.
Follow step 9 under MANUAL OPERATING Lighting Instructions.
INSPECTING FLAME PATTERN
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot
flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools,
the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 25.
•
Turn heater off (see TO TURN OFF GAS TO APPLIANCE)
•
See Troubleshooting (page 20).)
Figure 24 - Correct Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. If burner
flame is incorrect:
•
Turn heater off (see "To Turn Off Gas To Appliance")
•
See Troubleshooting (page 20).
Approx.3-6 inches
above top of logs
Figure 26 - Correct Flame Pattern
with heater set to High Flame
to "ON" position. Do not operate between locked positions.
Figure 25 - Incorrect Pilot Flame Pattern
7
to the OFF position. Do not force.
to ELECTRIC position.
More Than 8 inches
above top of logs
Figure 27 - Incorrect Flame Pattern
with heater set to High Flame
to OFF position for one
Need help?
Do you have a question about the SSU220RHN-GB and is the answer not in the manual?
Questions and answers