Service; Lamp - Martin CX-10 Extreme User Manual

Table of Contents

Advertisement

S
ERVICE
The CX-10 requires regular maintenance to keep performing at their peak. Excessive dust, grease, and
smoke fluid buildup degrades performance and causes overheating and damage that is not covered by the
warranty. The maintenance schedule will depend on the application and should be discussed with your
Martin distributor. Refer any service that is not described here to a professional technician.
Warning!
Removing covers while the fixture is powered on exposes dangerous live electrical
circuits, hot surfaces, and a lamp under high pressure. Disconnect the fixture from AC
power and allow it to cool before removing any cover.

Lamp

Lamp life will vary; the rated life is an average figure that is based on the manufacturer's test cycle. For
maximum lamp life, avoid excessive strikes and always allow the lamp to burn for at least 5 minutes before
turning it off.
To reduce the risk of lamp explosion, which may damage the fixture, never exceed the lamp's rated life
(3000 hours) by more than 25 percent.
Replace the lamp when:
• it strikes with difficulty or not at all, or is in any other way defective
• usage exceeds the manufacturer's "replace before" hours. See Table 3.
C O M P A T I B L E L A M P S
A Philips MSD 250/2 lamp is included. The CX-10 lamp options are shown in the table below. Installing any
other lamp may damage the fixture.
Lamp
Osram HSD 250
Philips MSD 250/2
Philips MSD 200
28
Average life
Color Temp.
2000 hr
6000K
3000 hr
8500K
2000 hr
5600K
Table 3: Lamp comparison
CX-10
Output
P/N
68 lm/W
97010103
72 lm/W
97010100
67 lm/W
97010106

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents