External Alarm Input And Relay Output - Nitro NVR4SGX User Manual

Nvr series
Table of Contents

Advertisement

and return main menu.
Note:
1)
If record type is "Motion Detect" or other related types, you must setup "Motion
Detection" in order to trigger motion recording (refer to chapter 5.10).
2)
If record type is "Alarm" or other related types, you must setup "Alarms" in order to
trigger alarm recording (refer to chapter 5.13).
3)
The time period is among 00:00—24:00.

5.13 External Alarm Input and Relay Output

For 8-channel DVR, there are 8 external alarm input and 4 relay output. For 16-channel DVR,
there are 16 external alarm input and 4 relay output. In "Alarms" menu, you can setup for each
external alarm input.
In main menu, move "Active Frame" to "Alarms" icon and press
alarms menu:
External alarm input setup:
Step 1: Select one alarm input Use
Step 2: Alarm type
This is sensor type. You can select "Normal Open" or "Normal Close" according to the
sensor type.
Step 3: Enter into "Alarm in Handling" sub menu
In the "Alarms" menu, there are two options for "Alarm Handling" item. One is "Ignore",
and the other is "Handle". If you select "Handle" option, you can active "Policy" and "PTZ
User Manual of NVR Series DVR
【 ↑ 】 【 ↓ 】
k eys to select one alarm input.
Total
65
104
P a g e
E NTER
k ey to enter into

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nvr16stxNvr8stxNvr16saxNvr8saxNvr16srx

Table of Contents