PC1550 Version 4.1
[29] Number of Rings Before Answering
Default
1 2
[30] Reset To Factory Default
[31] 4th System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
OFF
Zone Light 5
OFF
Zone Light 6
• • • • • If zone light 4 is ON, bypass status will always be shown. If zone light 4 is OFF, bypass status is shown only when the panel is disarmed.
[32] 5th System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
ON
Zone Light 3
OFF
Zone Light 4
OFF
Zone Light 5
ON
Zone Light 6
[33] Answering Machine Double Call Timer
Default
0 6 0
[34] 6th System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
OFF
Zone Light 5
OFF
Zone Light 6
[35] LINKS1000 Test Reporting Code
Default
NOTE: The LINKS1000 is not UL listed.
F F
[36] Keypad Lockout Control
Default
Enter 2 2-digit numbers in the range of 00 to 99. Program the Number of Invalid Codes as "00" to disable the lockout feature.
0 0
0 0
[90] Installer's Lockout Enable
[91] Installer's Lockout Disable
WARNING! Panels returned to DSC with the Installer's Lockout enabled and no other apparent problems will be subject to an
additional service charge!
Enter a number from 01 to 12 to set the number of rings before the panel will answer.
Page 13
Page 14
Zone Light ON
Enable download answer
Enable download callback
Answering machine over-ride
Show bypass status/armed
AC = 50 Hz
Restore on bell time out
Page 14
Zone Light ON
AC excluded from trouble
No bell during auto-arm
Home/away with delay
Quick exit enabled
Force arm on auxiliary delay
Standard Fire
Valid entries are "001" to "249"
Page 14
Zone Light ON
Audible Exit Delay with Urgency
Bell Squawk during Exit Delay
Audible Exit Fault enabled
Urgency applied to Entry Delay
Bell Squawk during Entry Delay
[F] Key disabled
Page 14
Program this section only if the LINKS1000 Cellular Alarm Transmitter is being used with the PC1550.
Page 14
Number of Invalid Codes before lockout
Lockout Duration (minutes)
Page 14
Page 14
Page 13
Zone Light OFF
Disable answer
Disable callback
Disable over-ride
1 1 1 1 1
Show bypass status/disarmed
AC = 60 Hz
Restore as follower
Zone Light OFF
AC included
Bell during auto-arm
Home/away as interior
Quick exit disabled
Auxiliary delay normal
Temporal Fire
Page 14
Zone Light OFF
Standard Exit Delay
No Bell Squawk during Exit Delay
Audible Exit Fault disabled
Standard Entry Delay
No Bell Squawk during Entry Delay
[F] Key enabled
19