Programming Work Sheets
NOTE: In sections [01] to [10], do not enter data into sections that are not used.
[01] 1st Phone Number
[02] 1st Account Code
Enter [ 1 ] (HEX A) for the digit "0" in the account code. For a 3-digit code, enter [0] for the 4th digit.
[03] 2nd Phone Number
[04] 2nd Account Code
[05] Zone Alarm Reporting Codes
For single digit reporting codes, enter [0] as the second digit. Enter [ 1 ] (HEX A) to transmit a "zero".
Zone 1 Alarm
Zone 2 Alarm
Zone 3 Alarm
[06] Zone Restoral Reporting Codes
For single digit reporting codes, enter [0] as the second digit. Enter [ 1 ] (HEX A) to transmit a "zero".
Zone 1 Restoral
Zone 2 Restoral
Zone 3 Restoral
[07] Closing (Arming) Reporting Codes / Partial Closing Reporting Code
Access Code 1
Access Code 2
Access Code 3
[08] Opening (Disarming) Reporting Codes / After Alarm Reporting Code
The "after alarm" code is sent on disarming if an alarm occured during the previous armed period.
Access Code 1
Access Code 2
Access Code 3
[09] Priority Alarms and Restorals
Pressing the [F], [A] or [P] keys will immediately transmit both an alarm and restoral code. There is no delay on the restoral code
transmission.
Fire Loop Trouble
Keypad [P]anic Alarm
Keypad [F]ire Alarm
Keypad [A]uxiliary Alarm
[10] Maintenance Alarms and Restorals
For automatic test code reporting, time between reports (in days) must be specified in Section [17], and time of day for the report
must be entered in Section [19]. NOTE: For UL installations, either AC failure or battery trouble reporting must be enabled.
Low Battery Alarm
AC Fail Alarm
PTC Failure Alarm
Low Battery Restore
Page 8
Enter [0] for the digit 0 in the phone number. Enter [ 4 ] (HEX D) for additional
dial tone detection between number digits, as in local PBX systems. Enter [#]
to end the phone number entry
Page 8
Page 9
NOTE: For UL installations, the second phone number must not be activated,
as the total number of dialing attempts would be greater than 10.
Page 9
Page 9
Page 9
Page 9
Page 10
Zone 4 Alarm
Zone 5 Alarm
Zone 6 Alarm
Zone 4 Restoral
Zone 5 Restoral
Zone 6 Restoral
Access Code 4
Access Code 5
Access Code 6
Partial Closing Code
Access Code 4
Access Code 5
Access Code 6
After Alarm Code
Fire Loop Trouble Restore
Keypad [P]anic Restore
Keypad [F]ire Restore
Keypad [A]uxiliary Restore
AC Fail Restore
PTC Failure Restore
Automatic Test Code