[11] Zone Definitions
NOTE: When defining zones, assign delay zones first to zones 1,2,3..., then assign the other zone types to the remaining zones
in any order desired.
Default
0 0
0 1
0 1
0 2
0 2
0 8
[12] 1st System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
ON
Zone Light 3
ON
Zone Light 4
OFF
Zone Light 5
ON
Zone Light 6
[13] 2nd System Option Code
Default
ON
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
OFF
Zone Light 5
OFF
Zone Light 6
1 1 1 1 1
Do not program "OFF" unless 2nd phone number is programmed.
2 2 2 2 2
With Bell Squawk enabled, the bell/siren will sound one short burst on arming and two short bursts on disarming.
[14] 3rd System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
ON
Zone Light 5
OFF
Zone Light 6
16
Page 10
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Page 11
Zone Light ON
Communicator disabled
TX limit to 24 hour period
Alarm display while armed
DTMF dialling
N.C. loops (except fire)
Keypad [P]anic audible (bell)
Page 11
Zone Light ON
Call 1st phone only
Master Code not changeable
Bell Squawk enabled
PC16 OUT enabled
6th code is maid's code
1400 Hz Radionics
Page 11
Zone Light ON
User code required for bypass
[ ] [4] Enabled
Periodic downloading
[ ] [4] access code required
[P]anic audible (buzzer)
Partial closing identified
First Digit
0 = Slow, Audible
1 = Slow, Silent
2 = Fast, Audible
3 = Fast, Silent
• • • • • Any one zone may be set as a FIRE zone.
Zone Light OFF
Communicator enabled
TX limit to armed period
No alarm display while armed
Pulse dialling
EOL resistor loops
Keypad [P]anic silent (bell)
Zone Light OFF
Backup to 2nd phone
Master Code changeable
2 2 2 2 2
Bell Squawk disabled
PC16 OUT disabled
6th code normal
2300 Hz Radionics
Zone Light OFF
Code not required
[ ] [4] Disabled
Periodic test transmit
[ ] [4] no code required
[P]anic silent (buzzer)
Not identified
PC1550 Version 4.1
Second Digit
0 = Standard Delay
1 = Instant
2 = Interior
3 = Interior, Home-Away
4 = 24 Hour Bell
5 = 24 Hour Bell/Buzzer
6 = 24 Hour Buzzer
7 = Aux. Delay (Uses Auxiliary Entry/
Exit Times)
8 = Fire•