DSC PC155O Installation Manual page 18

Hide thumbs Also See for PC155O:
Table of Contents

Advertisement

PC1550 Version 4.1
[15] Communication Variables
Default
NOTE: For UL installations, the Maximum Transmissions section cannot be enabled. Also, the Delay Before Transmission
must not exceed 15 seconds.
0 3
Enter digits from "01" to "99" for number of transmissions per zone during the period as defined in Section [12], 1st System
Option Code, Zone Light 2. Note that "00" = unlimited transmissions per burglary zone. Fire zone always transmits.
Default
0 0
Enter digits from "01" to "99" - delay in seconds; "00" = no delay. Fire zone and 24 hour zone transmissions cannot be
delayed. Transmission delay as programmed here is for burglary zones only.
[16] Zone Bypass Mask
If the zone light is ON, the zone can be bypassed using the [ ][1] command. If a zone is defined as a fire zone, it cannot
be bypassed.
Default
ON
Zone Light 1
ON
Zone Light 2
ON
Zone Light 3
[17] System Times
Default
0 3 0
1 2 0
0 0 4
Valid entries are "001" to "255". Do not enter "000".
[18] Auxiliary Delay Loop Entry / Exit Times
Default
0 4 5
1 2 0
[19] System Clock Times
Default
9 9 9 9
9 9 9 9
Enter 4 digits - "00" to "23" hours; "00" to "59" minutes. If a feature is not used, leave at the default setting of "9999".
For Sections [20], [21] and [22]: Enter 4 digits from "0" to "9". Do not enter [ ] or [#].
[20] New Installer's Code
Default
1 5 0 0
[21] New Master Code
Default
1 2 3 4
[22] 2nd Master Code
Default
A A A A
Page 11
Maximum transmissions per burglary zone
Delay before transmission (burglary zones only)
Page 11
Default
Page 11
Entry Delay (seconds)
Exit Delay (seconds)
Bell Cut-off (minutes)
Do not enter "000".
Do not enter "000".
Do not enter "000".
Do not enter "000".
Entry Time (seconds)
Exit Time (seconds)
Page 12
Automatic Arming (time of day)
Test transmission or auto download (time of day)
Page 12
Page 12
Page 12
The 2nd Master Code can be erased by entering [ 1111]. AAAA = not programmed
ON
Zone Light 4
ON
Zone Light 5
ON
Zone Light 6
Default
0 3 0
AC fail transmission delay (minutes)
0 5 0
Slow loop response time ( x 10 ms)
0 3 0
Test transmission cycle or auto download
cycle time (days)
Page 12
Valid entries are "001" to "255".