Connecting To A Masonry Chimney; Connecting To A Steel Chimney; Fresh Air Supply - Morso 3610 Instructions And Operating Instructions

Table of Contents

Advertisement

1.7 Connecting the stove to a masonry chimney
A wall sleeve should be bricked securely into the wall of the chimney at the appropriate height
and the stovepipe inserted centrally. The pipe must not extend into the actual chimney open-
ing, but rather must reach only to the inside of the chimney aperture. The gap between the
stovepipe and sleeve must be sealed using glass fibre packing rope. It is normally not neces-
sary to seal between any pipe joints.
If the flue transitions from horizontal to vertical, it is helpful to install it with a gentle bend so
as to avoid loss of draught.
Only use stovepipe components that comply to National and Local Building Regulations.
Morsø recommends, however, that flues made of  mm sheet steel, as this will extend the
servece life of the flue.
1.8 Connecting to a stainless steel insulated chimney system
If your installation involves taking the chimney straight up and through the ceiling, you must
comply with National, Local Building Regulations or flue manufacturers instructions concern-
ing clearances to combustible materials such as walls, floor joists and ceilings. The joint be-
tween the stove flue collar and the stovepipe must also be sealed using the glass fibre rope
provided. It is important that the insulated flue system is properly supported both at ceiling
level and at roof level. THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYS-
TEM (See chimney manufacturer's instructions). Excessive weight on the stove will inhibit ex-
pansion and could lead to damage of the stove top. Damage caused to the stove in this way
would not be covered by the manufacturers warranty scheme.
In the event that a chimney fire occurs as a result of faulty operation or prolonged use of
damp wood fuel, close the air vents completely and contact your local fire department im-
mediately.
Be aware of the following:
Cleaning procedure: Discuss this with chimney sweep or qualified installer prior
to or during the stove installation
Chimney draft: If the chimney draft is naturally poor it is better to install the flue
from the top of the stove so as to minimise any internal resistance of the flue
gases.
Avoid having any more than 2 bends in the flue system and limit the length of the
offset between bends.

Fresh air supply

A wood-burning stove requires air for combustion and therefore you may need to
install additional ventilation to the room, especially so in well insulated houses. If
the air supply in inadequate the chimney draft may be too weak, with the pos-
sible result that the stove will not burn properly; smoke spillage may also occur
during the refuelling process.
On a positive note, a properly installed wood-burner will give even the most ef-
ficient houses a pleasant and natural ventilation.