If something is wrong, just give us a call or send an email. We’ll be happy to help, honest. Blizzard Lighting W220 N1531 Jericho Ct. Ste E Waukesha, WI 53186 USA www.blizzardlighting.com 414-395-8365 Page 3 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
• Avoid direct eye exposure to the light source while it is on. Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact Blizzard Lighting at support@blizzardlighting.com. Page 4 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Dimmer Red Intensity Green Intensity Blue Intensity White Intensity Strobe Built-in Programs DMX Quick Reference (4-Channel Mode) Channel Channel Red Intensity Green Intensity Blue Intensity White Intensity Page 5 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Under normal operating conditions, the fuse should not require replacement. The fuse is field replaceable, however it is an advanced procedure suited to qualified individuals. Should your ProPar Seven.4™ fuse require replacement, please contact Blizzard Lighting for instructions, or to return your unit for service. Connecting A Bunch of ProPar Seven.4™ Fixtures You will need a serial data link to run light shows using a DMX-512 controller or to run shows on two or more fixtures set to sync in master/slave operating mode.
We recommend connecting the fixtures in terms of their proximity to the controller, rather than connecting the lowest fixture number first, and so on. Step 3: Connect other fixtures in the chain from output to input as above. Place a DMX terminator on the output of the final fixture to ensure best communication. Page 8 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Do not mount to surfaces with unknown strength, and ensure properly “rated” rigging is used when mounting fixutres overhead. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs. • When selecting installation location, take into consideration lamp replacement access (if applicable) and routine maintenance. • Safety cables MUST ALWAYS be used. • Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Page 9 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Press the <ENTER> button to select the menu function currently displayed, or to enable a menu option. To return to the previous option or menu without changing the value, press the <MENU> button. Page 10 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Static TEAL CO13 Static PINK CO14 Static WARM WHITE CO15 Static ROSE FADE SP - Adjust fade speed (1-8) NANU Static RED dimmer GREE Static GREEN dimmer BLUE Static BLUE dimmer Uh1t Static WHITE dimmer FHRS To check the fixture’s used time Page 11 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
2.) Then use the <UP/DOWN> buttons to scroll to either (red), GREE BLUE Uh1t (green), (blue), or (White), and press <ENTER>. 0-255 Select the maximum level for each color between (0=off), then hit <ENTER> to confirm. Page 12 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Fixture Not Make sure all connectors are seated properly and securely. Responding / Use Only DMX Cables. Responding Er- Install a Terminator. raticly Check all cables for defects. Reset fixture(s). Page 13 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
DMX source. Generally, the “Secondary” channel is not used so data flows only from sources to receivers. Hence, most of us are most familiar with DMX-512 as being employer over typical 3-pin “mic cables,” although this does not conform to the defined standard. Page 14 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...
Damage incurred in shipping is the responsibility of the shipper, and must be reported to the carrier immediately upon receipt of the items. Claims must be made within seven (7) days of receipt. Page 16 ProPAR 7.4 Manual Rev. A Copyright (c) 2012 Blizzard Lighting, LLC...