IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
PLEASE SAVE THESE INSTRUCTIONS.

SAFETY NOTICE

If this fi replace is not properly installed, a
house fi re may result. For your safety, follow
the installation instructions. Contact local
building or fi re officials about restrictions
and installation inspection requirements in
your area.
TESTED and LISTED to CAN/ULC
S610-M87 AND UL 127
Meets the Environmental Protection
Agency's July 1990 Particulate Emission
Standards
261114-28
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD. - 2014
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL: FP30, FP30AR
SERIES: B
ZERO CLEARANCE WOOD
FIREPLACE
FP30, FP30AR
SERIAL #
5055.5152

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy FP30

  • Page 1: Safety Notice

    INSTALLATION AND OPERATING INSTRUCTIONS TESTED and LISTED to CAN/ULC S610-M87 AND UL 127 Meets the Environmental Protection Agency's July 1990 Particulate Emission Standards MODEL: FP30, FP30AR SERIES: B ZERO CLEARANCE WOOD FIREPLACE 261114-28 ©PACIFIC ENERGY FIREPLACE FP30, FP30AR 5055.5152 PRODUCTS LTD. - 2014...
  • Page 2: Table Of Contents

    If this fi replace is not Fireplace Installation ..............10 properly installed, a Clearances ...................10 house fi re may result. Crate Removal ..................10 Locating The FP30 Fireplace ..............10 For your safety, fol- Procedure:.....................11 low the installation Dimensions .................11 Minimum Framing Dimensions..........12 instructions.
  • Page 3: Safety And Maintenance

    Periodically inspect seals and replace if necessary. 7. DOOR GLASS - Replacement glass can be obtained from your dealer. Use 11 3/8"(289mm) x 21 5/8"(549mm) x 5 mm ceramic glass only. PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 4: Maintenance Checks

    The blower is accessed through the access covers located in the bottom of the and the air box beneath the fi rebox ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 5: Blower Replacement

    #4). 10. Reverse the process to re-install blower. Make sure the gasket is in good condition. Replace if needed. TERMINAL GROUND WIRE BLOCK WINGNUTS FIG. #4 NUTS TO SWITCH OR SPEED CONTROLLER PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 6: Creosote

    Contact your local municipal or provincial fi re authority for further information on how to handle a chimney fi re. It is most important that you have a clearly understood plan on how to handle a chimney fi re. ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 7: Operation

    2. To refuel, adjust air control all the way to the left(High), Your PACIFIC ENERGY fi replace is designed for maximum and give the fi re time to brighten. Open the door slowly, overall efficiency at a moderate fi ring rate. Over fi ring is this will prevent back puffing.
  • Page 8: Over Firing

    It is also recommended that the blower be wired to a wall switch or 3amp approved Fan Speed Controller for manual control. ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 9: Firebrick Installation

    9” X 3 1/2” X 1 1/4” (102 mm x 115 mm x 32 mm) 3245.501 7 1/4” X 4 1/2” X 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 10: Fireplace Installation

    - DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. The FP30 fi replace may not be installed in a factory built fi replace unless tested with the fi replace. The fi replace is not tested. - DO NOT INSTALL IN A SLEEPING ROOM.
  • Page 11: Procedure

    27 1/2" FIG. #6 [699mm] FP30 & 30 3/4" [781mm] 23" FP30AR [584mm] 47" [1.19m] 30 1/8" 34 7/8" [765mm] [886mm] 23 7/8" [606mm] 13 1/4" 9 5/8" [337mm] [245mm] 42" [1.07m] PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 12: Minimum Framing Dimensions

    DIMENSIONS AROUND THE TO REAR WALL FIREPLACE INCLUDE THE INNER DRYWALL BOARD. 24" 610mm 56" 1.42m 73" 1.85m " 641mm " 137mm 73" " 1.85m 905mm " 2.62m " 1.61m 56" 1.42m ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 13: Framing Kit Assembly

    Using the screws provided (1), attach the framing kit legs(4) to the bottom stud (2). • Next, attach each center support(3) to the bottom stud(2) and then attach the top stud(2) to the center supports(3). FIG. #8 PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 14 Fireplace Anchor Plate O p t i o n a l A n c h o r Plate spacer may be required with some chimney brands. Non-combustible fl oor protector ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 15: Chimney Installation

    WALL AND CEILING/ROOF MUST BE MAINTAINED. NOTE: Check local codes concerning installation requirements and restrictions in your area. NOTE: The FP30 can be installed with a minimum 15ft(4.5m) of chimney with or without offsets. NOTE: Combustible materials cannot be used in the space directly above the fi replace.
  • Page 16: Offsets

    Offsets The chimney for the FP30 can be installed with a maximum FIG. #10 of four 45° elbows(in Canada) and four 30° elbows(in U.S.A.) as shown in Fig. #10. Installation: 1. Install the fi rst elbow; turn it in the required direction. It INSTALL SUPPORTS AS PER is required to secure connections with three (3) #8 x ½"...
  • Page 17: Combustion Air

    To draw outside combustion air, connect the cover plate on the side you do not wish to draw the air from and con- nect the outside combustion air adapter(FP30.OAIR) to the side you wish to draw air from. (Both cover plate and adpater provided) (Fig.
  • Page 18: Floor Protector

    2” 51mm Floor Blower Wiring 18" [457mm] The FP30 must be connected 120 VAC household electrical 8" [203mm] 8" [203mm] system. Non-combustible fl oor protector It is recommended to also connect the unit to a wall switch or fan speed controller.(1.1 amp load or greater)
  • Page 19: Remote Heat Duct Installation

    2. Insert a remote heat fl ap box in the opening/s that you are attaching a kit to. Attach the heat duct adapter/s with the screws provided in the WODC.RHKA (Fig. #17). PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 20: Electrical Wiring

    WIRED TO A SEPARATE SWITH OR SPEED CONTROL- LER THAN THE CONVECTION BLOWERS ON THE UNIT. FIG. #18 BLOWER SPEED 120 VOLTS 60 Hz CONTROL 0.7 AMPERES G (green) L1 (white) L2 (black) USE ONLY COPPER CONDCUTORS ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 21 CHIMNEY INSTALLTIONS NOT SHOWN ROUND DUCT (6”(150mm) TYPE ”B”) MAXIMUM DUCT LENGTH 20’(6.1m). PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 22: Facing And Air Inlet

    Facing and Air Inlet Cement Board Installation FIG. #20 The front facing area of the FP30 must be covered with non- combustible cement board as shown in Fig.#20 and #21 prior to applying any fi nishing material. The cement board can be attached to the framing and to the front of the unit outside of the dimensioned area shown by the dotted line in Fig.#20.
  • Page 23: Mantel Clearances

    52 1/2"(1.33m) 8"(203mm) 53"(1.35m) 18"(457mm) 9"(229mm) 53 1/2"(1.36m) 10"(254mm) 54"(1.37m) 19"(483mm) 11"(279mm) 54" 1/2”(1.38m) 12"(305mm) 55"(1.4m) 20"(508mm) Combustible Mantle (A) 12"(305mm) (A)4"(102mm) 7’(2.13m) Floor to ceiling Minimum (B) 55" 1.4m (B) 51" 1.3m PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 24: Troubleshooting

    1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer ©PACIFIC ENERGY FIREPLACE PACIFIC FP30 261114-28 PRODUCTS LTD.
  • Page 25: Understanding & Operating Your Pacifi C Energy Fireplace

    1 -Boost Air 4 -Secondary Combustion Zone 2 -Main Combustion Air 5 -Radiant Heat 3 -Air Wash System 6 -Convected Heat PACIFIC FP30 261114-28 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 26: Replacement Parts

    *21 ..Outside Air Adapter ....... FP30.OAIR 3.... Blowers.......... (R)FP30.502453 *22 ..Access Cover Gasket ......5068.81016 ..............(L)FP30.502454 *23 ..Gravity Heat Duct Adapter ...... FP30.9128 4.... Firebrick Set ...........BRIC.FP30 *24 ..Anchor plate spacer(for use with ICC Chimney olny) 5.... Door Gasket ........FP30.DGKIT ................
  • Page 27: Label Location

    • BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS. • DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
  • Page 28 PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Phone: 250-748-1184 Web site: http://www.pacifi cenergy.net Printed in Canada ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.