PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacifi c Energy, FP16 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015. Un- der specifi c test conditions this heater has been shown to deliver heat at rates ranging from 10,800 to 24,600 Btu/hr.
This heater is not designed for open door burning. Your PACIFIC ENERGY heater is designed for maximum If unit is operated with the door open, gases and fl ame overall efficiency at a moderate fi ring rate. Over fi ring is may be drawn out of the fi replace opening creating risks hazardous and a waste of fuel.
72"(1.83m) measured from the base of the appliance to the ceiling is required. The FP16 fi replace may not be installed in a factory built fi replace unless tested with the fi replace. Wind direction and magnitude can play a factor in the chimney performance.
MANUFACTURER'S FIREPLACE ANCHOR PLATE. NOTE: Check local codes concerning installation requirements and restrictions in your area. NOTE: The FP16 must be installed so the outlet of the chimney system is a minimum 15ft(4.6m) in height as measured from the base of the unit.
NOTE: IT IS REQUIRED THAT ALL CHIMNEY SYSTEM CONNECTIONS BE SECURED WITH (3)-#8 X ½"(12 MM) The chimney for the FP16 can be installed with a maximum METAL SCREWS. of four 45° elbows(in Canada) and four 30° elbows(in FIG. #10 U.S.A.) as shown in Fig.
The wood framing must be installed as shown below with no wood framing directly in front of the chimney. The front facing area of the FP16 must be covered with The cement board must cover from the fl oor to the ceiling non-combustible cement board prior to applying any non- and the full width of the unit(42"(1.07m)).
Floor Blower Wiring 18" [457mm] 8" [203mm] 8" [203mm] The FP16 blowers must be connected to 120 VAC house hold electrical system. Non-combustible fl oor protector It is recommended to also connect the circuit to a wall switch or fan speed controller.(not supplied) 49 1/2"...
ITEM DESCRIPTION PART NO. 1.... Quadrant ............7953 13 ..Front Trim Plate, Black ......FP16 .F T M B K A 2.... Blower Assembly, LHS ......NE16.7844 Front Trim Plate, Stainless Steel ......FP16.FTSSA ....Blower only, LHS ........5024.701 14 ..Firebrick Set ........NE16.INSBRIC 3....
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS. • DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT. • THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET.
Page 28
PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, B.C. V9L 6V8 For technical support, please contact your retailer. Web site: http://www.pacifi cenergy.net Printed in Canada...